Parameter Descriptions
14-55 Output Filter
Option:
Function:
NOTICE
This parameter cannot be changed
while the motor is running.
Select the type of output filter connected.
[0]
No Filter
*
[1]
Sine-Wave Filter
4.13.7 14-6* Auto Derate
Use this parameter group to configure automatic derating
for the output current of the frequency converter.
14-61 Function at Inverter Overload
When the frequency converter issues a frequency converter
overload warning, select whether to continue and trip the
frequency converter, or derate the output current.
Option:
[0]
Trip
*
[1]
Derate
14-63 Min Switch Frequency
Option:
Function:
Set the minimum switch frequency allowed by
the output filter.
[2]
2.0 kHz
*
[3]
3.0 kHz
[4]
4.0 kHz
[5]
5.0 kHz
[6]
6.0 kHz
[7]
8.0 kHz
[8]
10.0 kHz
[9]
12.0 kHz
[10] 16.0 kHz
14-64 Dead Time Compensation Zero Current Level
Option:
Function:
[0]
Disabled
*
[1]
Enabled If using a long motor cable, select this option to
minimize the motor torque ripple.
14-65 Speed Derate Dead Time Compensation
Range:
Function:
Size
[ 20 -
Deadtime compensation level is reduced
related
1000 Hz]
linearly versus output frequency from
*
the maximum level set in
parameter 14-07 Dead Time Compen-
sation Level to a minimum level set in
this parameter.
MG06C702
Programming Guide
4.13.8 14-8* Options
14-89 Option Detection
Selects the behavior when an option change is detected. This
parameter returns to [0] Protect Option Config. after an option
change.
Option:
[0]
[1]
4.13.9 14-9* Fault Settings
Use the parameters to configure the fault settings.
14-90 Fault Level
Function:
Use this parameter to customize fault levels. Use the 8
to control the fault level of alarm 13, Overcurrent.
Option:
[3]
[4]
[5]
Index
0
1
2
3
4
5
6
7
Table 4.10 Table for Selection of Action when
Selected Alarm Appears (Parameter 14-90 Fault Level)
D = Default setting
x = Possible selection
Danfoss A/S © 06/2017 All rights reserved.
Function:
Protect Option Config. Freezes the current settings and
*
prevents unwanted changes when
missing or defective options are
detected.
Enable Option
Settings can be changed when the
Change
system configuration is being
modified.
Function:
Trip Lock
Alarm is set to trip lock.
*
Trip w.
Alarm is configured into trip alarm, which
delayed reset
can be reset after a delay time. For
example, if alarm 13, Overcurrent is
configured to this option, it can be reset 3
minutes after the alarm.
Flystart
At start-up, the frequency converter tries to
catch a spinning motor. If this option is
selected, parameter 1-73 Flying Start is
forced to [1] Enabled.
Alarm
Trip lock
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Overcurrent
D
4
th
element
Trip w.
Flystart
delayed
x
x
105
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents