Danfoss VLT AutomationDrive FC 360 Programming Manual page 62

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Parameter Descriptions
[163] Pos. Idx
Bit1
[164] Pos. Idx
Bit2
[165] Core
diameter
4
4
source
[166] New
diameter
select
[167] Reset
diameter
[168] Winder jog
forward
[169] Winder jog
reverse
[170] Tension on Enables tension PID control. This option is
60
®
VLT
Position index bit 1. This option is only
effective when parameter 37-00 Application
Mode is set to [2] Position Control.
Position index bit 2. This option is only
effective when parameter 37-00 Application
Mode is set to [2] Position Control.
The core diameter source. off means core 1 is
selected, and on means that core 2 is
selected. This option is only effective when
parameter 37-00 Application Mode is set to [1]
Center winder.
Configures whether to select partial roll
diameter (off) or core diameter (on). This
option is only effective when
parameter 37-00 Application Mode is set to [1]
Center winder.
Resets the diameter. This option is only
effective when parameter 37-00 Application
Mode is set to [1] Center winder.
Enables jog forward during center winding.
This option is only effective when
parameter 37-00 Application Mode is set to [1]
Center winder.
Enables jog reverse during center winding.
This option is only effective when
parameter 37-00 Application Mode is set to [1]
Center winder.
only effective when
parameter 37-00 Application Mode is set to [1]
Center winder.
Danfoss A/S © 06/2017 All rights reserved.
AutomationDrive FC 360
5-10 Terminal 18 Digital Input
Option:
Function:
[8]
Start Functions are described in parameter group 5-1*
*
Digital Inputs.
5-11 Terminal 19 Digital Input
Option:
[10]
Reversing Functions are described in parameter group 5-1*
*
5-12 Terminal 27 Digital Input
Option:
[2]
Coast inverse Functions are described in parameter group
*
5-13 Terminal 29 Digital Input
Option:
[14]
Jog
*
[32]
Pulse input
5-14 Terminal 32 Digital Input
Option:
[0]
No operation
*
[82] Encoder input B
5-15 Terminal 33 Digital Input
Option:
[0]
No operation
[16]
Preset ref bit 0
*
[32]
Pulse input
[81]
Enocder input A
5-16 Terminal 31 Digital Input
Option:
[0] No operation Functions are described in parameter group
Function:
Digital Inputs.
Function:
5-1* Digital Inputs.
Function:
Functions are described in parameter group
5-1* Digital Inputs.
Function:
Functions are described in parameter
group 5-1* Digital Inputs.
Function:
Functions are described in parameter
group 5-1* Digital Inputs.
Function:
5-1* Digital Inputs.