Parameter Descriptions
9-16 PCD Read Configuration
Select the parameters to be assigned to PCD 3–10 of the
telegrams. The number of available PCDs depends on the
telegram type. Values in PCD 3–10 contain the actual data values
of the selected parameters.
Option:
[1630]
DC Link Voltage
[1633]
Brake Energy /2 min
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1638]
SL Controller State
[1639]
Control Card Temp.
[1650]
External Reference
[1652]
Feedback[Unit]
[1653]
Digi Pot Reference
[1657]
Feedback [RPM]
[1660]
Digital Input
[1661]
Terminal 53 Setting
[1662]
Analog input 53
[1663]
Terminal 54 Setting
[1664]
Analog input 54
[1665]
Analog output 42 [mA]
[1667]
Pulse input 29 [Hz]
[1668]
Pulse input 33 [Hz]
[1669]
Pulse output 27 [Hz]
[1670]
Pulse output 29 [Hz]
[1671]
Relay output
[1672]
Counter A
[1673]
Counter B
[1679]
Analog output 45 [mA]
[1684]
Comm. Option STW
[1685]
FC Port CTW 1
[1690]
Alarm Word
[1691]
Alarm Word 2
[1692]
Warning Word
[1693]
Warning Word 2
[1694]
Ext. Status Word
[1695]
Ext. Status Word 2
[1697]
Alarm Word 3
[3421]
PCD 1 Read For Application
[3422]
PCD 2 Read For Application
[3423]
PCD 3 Read For Application
[3424]
PCD 4 Read For Application
[3425]
PCD 5 Read For Application
[3426]
PCD 6 Read For Application
[3427]
PCD 7 Read For Application
[3428]
PCD 8 Read For Application
[3429]
PCD 9 Read For Application
[3430]
PCD 10 Read For Application
[3450]
Actual Position
[3456]
Track Error
MG06C702
Programming Guide
9-18 Node Address
Range:
126
[ 1 -
*
126 ]
Function:
9-19 Drive Unit System Number
Range:
1037
*
9-22 Telegram Selection
Select a standard PROFIBUS telegram configuration for the
frequency converter as an alternative to the freely configurable
telegrams in parameter 9-15 PCD Write Configuration and
parameter 9-16 PCD Read Configuration.
Option:
[1]
[100]
*
[101]
[102]
[103]
[104]
[105]
[106]
[107]
[108]
[200]
9-23 Parameters for Signals
Option:
[0]
*
[302]
[303]
[311]
[312]
[341]
[342]
[351]
[352]
[380]
[381]
[412]
[414]
[416]
[417]
[553]
[558]
[590]
[593]
[595]
[615]
Danfoss A/S © 06/2017 All rights reserved.
Function:
Enter the station address in this parameter or,
alternatively, in the hardware switch. To adjust the
station address in parameter 9-18 Node Address,
set the hardware switch to 126 or 127 (that is all
switches set to on). Otherwise, this parameter
shows the actual setting of the switch.
Function:
[0 - 65535 ]
Manufacturer specific system ID.
Standard telegram 1
None
PPO 1
PPO 2
PPO 3
PPO 4
PPO 5
PPO 6
PPO 7
PPO 8
Custom telegram 1
None
Minimum Reference
Maximum Reference
Jog Speed [Hz]
Catch up/slow Down Value
Ramp 1 Ramp Up Time
Ramp 1 Ramp Down Time
Ramp 2 Ramp Up Time
Ramp 2 Ramp Down Time
Jog Ramp Time
Quick Stop Ramp Time
Motor Speed Low Limit [Hz]
Motor Speed High Limit [Hz]
Torque Limit Motor Mode
Torque Limit Generator Mode
Term. 29 High Ref./Feedb. Value
Term. 33 High Ref./Feedb. Value
Digital & Relay Bus Control
Pulse Out 27 Bus Control
Pulse Out 29 Bus Control
Terminal 53 High Ref./Feedb. Value
4
Function:
Function:
85
4