Parameter Lists
5.2.6 5-** Digital In/Out
Par. No. # Parameter description
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-16
Terminal 31 Digital Input
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
5-31
Terminal 29 Digital Output
5-34
On Delay, Digital Output
5-35
Off Delay, Digital Output
5-4* Relays
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-55
Term. 33 Low Frequency
5-56
Term. 33 High Frequency
5-57
Term. 33 Low Ref./Feedb. Value
5-58
Term. 33 High Ref./Feedb. Value
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
5-62
Pulse Output Max Freq 27
5-63
Terminal 29 Pulse Output Variable
5-65
Pulse Output Max Freq 29
5-7* 24 V Encoder Input
5-70
Term 32/33 Pulses Per Revolution
5-71
Term 32/33 Encoder Direction
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
5-93
Pulse Out 27 Bus Control
5-94
Pulse Out 27 Timeout Preset
5-95
Pulse Out 29 Bus Control
5-96
Pulse Out 29 Timeout Preset
MG06C702
Programming Guide
Default value
[0] PNP
[0] Input
[0] Input
[8] Start
[10] Reversing
ExpressionLimit
[14] Jog
[0] No operation
[16] Preset ref bit 0
[0] No operation
[0] No operation
[0] No operation
0.01 s
0.01 s
ExpressionLimit
0.01 s
0.01 s
4 Hz
32000 Hz
0 N/A
ExpressionLimit
4 Hz
32000 Hz
0 N/A
ExpressionLimit
[0] No operation
5000 Hz
[0] No operation
5000 Hz
1024 N/A
[0] Clockwise
0 N/A
0%
0%
0%
0%
Danfoss A/S © 06/2017 All rights reserved.
2-set-up
Change
Conversio
during
n index
operation
1 set-up
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
-2
1 set-up
TRUE
-2
All set-ups
TRUE
-2
1 set-up
TRUE
-2
Type
–
Uint8
–
Uint8
–
Uint8
–
Uint8
5
5
–
Uint8
–
Uint8
–
Uint8
–
Uint8
–
Uint8
–
Uint8
–
Uint8
–
Uint8
Uint16
Uint16
–
Uint8
Uint16
Uint16
0
Uint32
0
Uint32
Int32
Int32
0
Uint32
0
Uint32
Int32
Int32
–
Uint8
0
Uint32
–
Uint8
0
Uint32
0
Uint16
–
Uint8
0
Uint32
Uint16
Uint16
Uint16
Uint16
133