Danfoss VLT AutomationDrive FC 360 Programming Manual page 93

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Parameter Descriptions
12-14 Link Duplex
Option:
Function:
Forces the duplex for each port to full or half
duplex. If parameter 12-12 Auto Negotiation is
set to [1] On, this parameter is read-only.
[0]
Half Duplex
[1]
Full Duplex
*
4.11.3 12-8* Other Ethernet Services
12-80 FTP Server
Option:
[0]
Disabled
*
[1]
Enabled
12-81 HTTP Server
Option:
[0]
Disabled
*
[1]
Enabled
12-82 SMTP Service
Option:
[0]
Disabled
*
[1]
Enabled
12-89 Transparent Socket Channel Port
Range:
Function:
4000
[0 - 65535 ] Configures the TCP port number for the
*
transient socket channel. This enables FC
telegrams to be sent transiently on Ethernet
via TCP. Default value is 4000. 0 indicates
disabled.
4.11.4 12-9* Advanced Ethernet Services
12-90 Cable Diagnostic
Option:
Function:
Enables/disables advanced cable diagnosis
function. If enabled, the distance to cable errors
can be read out in parameter 12-93 Cable Error
Length. The parameter resumes to the default
setting [0] Disable after the diagnostics have
finished.
NOTICE
The cable diagnostics function is only
issued on ports where there is no link (see
parameter 12-10 Link Status).
[0]
Disabled
*
[1]
Enabled
MG06C702
Programming Guide
Function:
Function:
Function:
Danfoss A/S © 06/2017 All rights reserved.
12-91 Auto Cross Over
Option:
Function:
NOTICE
Disabling of the auto-crossover function
requires crossed Ethernet cables for daisy-
chaining the options.
[0]
Disabled Disables the auto-crossover function.
[1]
Enabled Enables the auto-crossover function.
*
12-92 IGMP Snooping
Option:
[0]
Disabled
[1]
Enabled
*
12-93 Cable Error Length
Range:
Function:
0
[0 -
If cable diagnostics is enabled in
*
65535 ]
parameter 12-90 Cable Diagnostic, the built-in
switch is possible via time domain reflectometry
(TDR). This is a measurement technique which
detects common cabling problems such as open
circuits, short circuits, and impedance mismatches
or breaks in transmission cables. The distance from
the option to the error is shown in meters with an
accuracy of ±2 m (6.6 ft). The value 0 means no
errors detected.
12-94 Broadcast Storm Protection
Range:
Function:
-1 %
[-1 -
The built-in switch is capable of protecting the
20 %]
switch system from receiving too many broadcast
*
packages, which can use up network resources. The
value indicates a percentage of the total
bandwidth that is allowed for broadcast messages.
Example:
OFF means that the filter is disabled - all broadcast
messages are passed through. The value 0% means
that no broadcast messages are passed through. A
value of 10% means that 10% of the total
bandwidth is allowed for broadcast messages. If
the amount of broadcast messages exceeds the
10% threshold, they are blocked.
12-95 Broadcast Storm Filter
Applies to parameter 12-94 Broadcast Storm Protection, if the
broadcast storm protection also includes multicast telegrams.
Option:
[0]
Broadcast only
*
[1]
Broadcast & Multicast
Function:
Function:
91
4
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents