System specific event IDs
Event ID
0xEC04
0xEC05
232
Description
2: Master system ID not valid
3: Slot not valid
4: Master configuration not valid
5: Master type not valid
6: Slave diagnostic address invalid
7: Slave address not valid
8: Slave module IO configuration invalid.
9: Logical address already in use.
10: Internal error
11: IO mapping error
12: Error
13: Error in initialising the EtherCAT stack (is entered by the CP)
PK : Not relevant to the user
DatID : Not relevant to the user
ZInfo2 : Error code higher 2 bytes
ZInfo3 : Error code lower 2 bytes
EtherCAT Multiple configuration of a periphery address
ZInfo1 : Periphery address
ZInfo2 : Slot
PK : Not relevant to the user
DatID : Not relevant to the user
EtherCAT: Check the set DC mode of the YASKAWA Sigma 5/7 drive
PK : Not relevant to the user
OB : Operation mode
0: Configuration in operation mode RUN
1: STOP (update)
2: STOP (overall reset)
3: STOP (own initialization)
4: STOP (internal)
5: Start-up (cold start)
6: Start-up (cold restart/warm start)
7: Start-up (restart)
8: RUN
9: RUN (redundant operation)
10: HALT
11: COUPLING
12: UPDATING
13: DEFECTIVE
VIPA System MICRO
HB400 | CPU | M13-CCF0000 | en | 16-47