System specific event IDs
Event ID
0xE009
0xE010
0xE011
0xE012
0xE013
0xE014
0xE015
0xE016
0xE017
0xE018
0xE019
0xE01A
0xE01B
0xE020
0xE030
0xE033
0xE0B0
0xE0C0
0xE0CB
214
Description
Error on accessing the standard backplane bus
There is a undefined module at the backplane bus
ZInfo2 : Slot
ZInfo3 : Type ID
Master project engineering at slave CPU not possible or wrong slave configuration
Error at parametrization
Error at shift register access to standard bus digital modules
Error at Check_Sys
Error at access to the master
ZInfo2 : Slot of the master
ZInfo2 : Page frame master
Maximum block size at master transfer exceeded
ZInfo1 : Periphery address
ZInfo2 : Slot
Error at access to integrated slave
Error at mapping of the master periphery
Error at standard back plane bus system recognition
Error at recognition of the operating mode (8 / 9 bit)
Error - maximum number of plug-in modules exceeded
Error - Interrupt information undefined
ZInfo2 : Slot
ZInfo3 : Not relevant to the user
DatID : Interrupt type
Error of the standard bus
Internal error - Please contact the hotline!
SPEED7 is not stoppable (e.g. undefined BCD value at timer)
ZInfo1 : Not relevant to the user
ZInfo2 : Not relevant to the user
ZInfo3 : Not relevant to the user
DatID : Not relevant to the user
Not enough space in work memory for storing code block (block size exceeded)
Error at SSL access
ZInfo1 : Error
4: SSL wrong
5: Sub-SSL wrong
6: Index wrong
ZInfo2 : SSL ID
ZInfo3 : Index
VIPA System MICRO
HB400 | CPU | M13-CCF0000 | en | 16-47