System specific event IDs
Event ID
0xEA69
0xEA6A
0xEA6B
0xEA6C
226
Description
ZInfo3 : Internal error code from PN stack
Internal error - Please contact the hotline!
PROFINET IO controller: Service error in communication stack
PK : Rack/slot
OB : Service ID
ZInfo1 : ServiceError.Code
ZInfo2 : ServiceError.Detail
ZInfo3 : StackError.Error.AdditionalDetail
ZInfo3 : ServiceError.AreaCode
PROFINET IO controller: Faulty vendor ID
ZInfo1 : Device ID
ZInfo2 : Not relevant to the user
ZInfo3 : Not relevant to the user
OB : Operation mode
0: Configuration in operation mode RUN
1: STOP (update)
2: STOP (overall reset)
3: STOP (own initialization)
4: STOP (internal)
5: Start-up (cold start)
6: Start-up (cold restart/warm start)
7: Start-up (restart)
8: RUN
9: RUN (redundant operation)
10: HALT
11: COUPLING
12: UPDATING
13: DEFECTIVE
14: Troubleshooting
15: Without power
0xFD: Process image enabled in STOP
0xFE: Watchdog
0xFF: Not set
PK : Rack/slot
DatID : Not relevant to the user
PROFINET IO controller: Faulty device ID
ZInfo1 : Device ID
PK : Rack/slot
VIPA System MICRO
HB400 | CPU | M13-CCF0000 | en | 16-47