The installation of the PROFINET IO devices 'VIPA MICRO PLC' happens in the hard-
ware catalog with the following approach:
1.
Go to the service area of www.vipa.com.
2.
Load from the download area at 'PROFINET files' the file Micro_Vxxx.zip.
3.
Extract the file into your working directory.
4.
Start the Siemens hardware configurator.
5.
Close all the projects.
6.
Select 'Options è Install new GSD file'
7.
Navigate to your working directory and install the according GSDML file.
ð After the installation according PROFINET IO device can be found at
'PROFINET IO è Additional field devices è I/O è VIPA MICRO PLC'
In the Siemens SIMATIC Manager the following steps should be executed:
1.
Start the Siemens hardware configurator with a new project.
2.
Insert a profile rail from the hardware catalog.
3.
Place at 'Slot' -Number 2 the CPU 314C-2 PN/DP (314-6EH04-0AB0 V3.3).
4.
Click at the sub module 'PN-IO' of the CPU.
5.
Select 'Context menu è Insert PROFINET IO System'.
6.
Create with [New] a new sub net and assign valid address data
7.
Click at the sub module 'PN-IO' of the CPU and open with 'Context menu
è Properties' the properties dialog.
8.
Enter at 'General' a device name. The device name must be unique at the Ethernet
subnet.
Deployment CPU M13-CCF0000
Hardware configuration - CPU
59