Configuration with VIPA SPEED7 Studio
SPEED7 Studio - Hardware configuration - Ethernet PG/OP channel
Take IP address parame-
ters in project
186
5.
Select 'Context menu è Determine accessible partner'.
ð A dialog window opens.
6.
Select the according network interface card, which is connected to the Ethernet
PG/OP channel and click at 'Search' to determine the via MAC address reachable
device.
ð The network search is started and the found stations are listed in a table.
7.
Devices...
1
2
Click in the list at the module with the known MAC address. This can be found at
the front of the CPU labelled as "MAC PG/OP: ...".
8.
Click at 'Set IP address' . Now set the IP configuration by entering 'IP address' ,
'Subnet mask' and 'Gateway' .
9.
Click at 'Set IP address' .
ð The IP address is transferred to the module and the list is refreshed. Directly
after the assignment the Ethernet PG/OP channel is online reachable using the
set IP address data. The value remains as long as it is reassigned, it is over-
written by a hardware configuration or a factory reset is executed.
10.
With clicking at 'Apply settings' the IP address data a stored in the project.
If you are not online, you can assign IP address data to your Ethernet PG/OP channel
with following proceeding:
1.
Start the SPEED7 Studio with your project.
2.
Click in the Project tree at 'Devices and networking' .
ð You will get a graphical object view of your CPU.
3.
Click at the network 'PG_OP_Ethernet' .
4.
Select 'Context menu è Interface properties'.
ð A dialog window opens. Here you can enter the IP address data for your
Ethernet PG/OP channel.
IP...
MAC...
172.20. ..
00:20: ...
...
...
HB400 | CPU | M13-CCF0000 | en | 16-47
VIPA System MICRO
Device...
...
...
VIPA ...
...