Copy Parameter Sets Via Bus (Fr.01, Fr.09) - KEB COMBIVERT R6-S Applications Manual

Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

3.7.5 Copy parameter sets via bus (Fr.01, Fr.09)

With indirect set addressing two parameters are responsible for copying parameter sets at bus operation. Fr.09
determines the target set. Fr.01 determines the source parameter set and starts the copy process. With direct
set-programming the source set (Fr.01) is copied in the selected parameter sets. The following copy functions
can be executed:
Target set
Source set
Fr.09
0...7
0
-1: dEF_S
1...7
-1: dEF_S
All
-2: dEF_A
0
-3: ini_S
1...7
-3: ini_S
All
-4: ini_A
All definitions defined by the machine builder are reset by loading the factory setting! This can include the ter-
minal assignment, set changeover or operating conditions. Ensure before loading the default set that there are
no unwanted operating conditions.
© KEB, 2008-02
Action
Fr.01
All set-programmable parameters (also system parameters) of the source
0...7
set are copied in the target set.
Default values are copied in all parameters of set 0 (exception system and
security parameters).
Default values are copied in all set-programmable parameters of the target
set (exception system and security parameters).
Default values are copied in all parameters of all sets (exception system
and security parameters).
Default values are copied in all parameters of set 0 (exception security
parameters).
Default values are copied in all set-programmable parameters of the target
set (exception security parameters).
Default values are copied in all parameters of all sets (exception security
parameters).
COMBIVERT R6-S
Parameter sets
3
10
Page3.7 - 5

Advertisement

Table of Contents
loading

Table of Contents