6.

Project Design

The following chapter shall assist you in the planning stage of applications.
6.1 General designs
6.1.1 Control cabinet design calculation
1
Main fuse
2
Main contactor
3
Commutation choke or harmonic filter
4
COMBIVERT R6
5
HF side-mounted filter (≥ size 25)
HF side-mounted filter (≤ size 19)
7
Frequency inverter
8
if necessary external DC fuses
9
Motor lines
10 A Protective Earth (PE) on the moun-
ting plate power circuit
10b
Protective Earth (PE) on the moun-
ting plate control circuit
10c
Equipotential bonding with the
housing earth
11
Mains connection power circuit
11 A Mains connection control circuit
12
Control lines
Large area contact at the mounting
plate
© KEB, 2008-02
COMBIVERT R6-S
Control circuit
Project design
Power circuit
Direction of the cooling
fins