Hardware
In order to prevent a malfunction caused by interference voltage supply on the control inputs, the following
directions should be observed:
•
Use shielded/drilled cables
•
Lay shield on one side of the inverter onto earth potential
•
Lay control and power cable separately (about 10...20 cm apart); Lay crossings in a right angle
EMC
(in case it cannot be prevented)
Active signal for further
R6-S units at parallel
max. 25 mA DC
per digital output
Seite 1.3 - 6
COMBIVERT R6-S
16
18
operation
Supply voltage of the
inputs
U
Analog output
0...±10 V DC / 5 mA
max. 30 V DC
0,01...2 A
Control release
max. 30 V DC
0,01...2 A
X2A
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
© KEB, 2008-02