KEB COMBIVERT R6-S Applications Manual page 84

Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

Digital in- and outputs
Value Function
59
Inputs AND linked (ru.22)
60
Inputs OR linked (ru.22)
61
Inputs NAND linked (ru.22)
62
Inputs NOR linked (ru.22)
Absolute value ANOUT1 >
63
level
65
ANOUT1 > level
73
Value actual power > level
74
Actual power > level
80
AC input current > level
Not listed values are not assigned.
Comparison level 0...7, LE.00...LE.07
These parameters define the switching levels of the different conditions.
Switching level 0 is valid for switching condition 0, switching level 1 is valid for switching condition 1... etc.
Hysteresis 0...7, LE. 08...LE.15
The hysteresis referring to the adjusted values determine parameters LE.08...LE.15.
Hysteresis 0 (LE.08) is valid for switching level 0; LE.09 for switching level 1... etc.
Seite 3.4 - 14
COMBIVERT R6-S
do.00...do.07: Conditions
Description
Function
Condition met when:
AND
all selected inputs active
OR
at least one selected input active
NAND
at least one selected input inactive
NOR
all selected inputs inactive
The selection of inputs to be linked is made by the comparison level parame-
ters LE.00...LE.07.
Input
ST
RST
F
R
Value
1
2
4
8
The sum of the inputs to query is entered in the switching levels.
Example: If condition F,R and I1 shall be linked to condition 0, value 4 + 8 +
16 = 28 must be entered in LE.00.
Value of ANOUT1 (amount of ru.34 „ANOUT1 post ampl. display) higher than
the switching level.
ANOUT1 (ru.34 „ANOUT1 post ampl. display) higher than the switching le-
vel.
Value ru.81 „actual power" > switching level
ru.81 „actual power" > switching level
I1
I2
I3
I4
IA
IB
16
32
64 128
256
512
IC
ID
1024
2048
© KEB, 2008-02

Advertisement

Table of Contents
loading

Table of Contents