3. Hardware Description of hardware, technical data of the inverter as well as connection of power and control terminals. The basic operation of the KEB COMBIVERT like password input, parameter and set 4. Operation selection. 5. Parameter A list of all parameters classified according to parameter groups.
Page 7
Preface ................1.1.13 1.1.3 Record of Changes ............1.1.15 Overview ....................2.1.3 Product Description ................2.1.3 2.1.1 Features of KEB COMBIVERT F4-F ........2.1.3 2.1.2 Function Principle ..............2.1.3 2.1.3 Application as directed ............2.1.4 2.1.4 Type Code ................2.1.5 2.1.5...
Page 19
Product Description Summary ANTRIEBSTECHNIK Overview Prog. Operator menu 2.1 Product Description Synchron running 8 parameter sets 2.1.1 Features of KEB Positioning control 17 parameter groups COMBIVERT F4-F Jogging-function (prog.) Software In-/Outputs Automatic control adjusting 1 prog. relay output COMBIVERT Inkremental encoder imitation 7 prog.
Page 20
Summary Product Description 2.1.3 Application as directed The KEB COMBIVERT is a frequency inverter with DC-voltage link. It works according to the principle of the pulse-width modulation and serves exclusively for the stepless speed regulation/control of three-phase AC motors. The unit has been developed subject to the relevant safety standards and is manufactured with the highest demands on quality.
Page 23
This data is only valid for units with internal brake transistor (see „2.1.4 Type Code“). At mains voltage ≥460V multiply the nominal current with factor 0,86. These units can be used with one or more braking modules. For more informations cantact KEB. Name: Basis...
Page 24
This data is only valid for units with internal brake transistor (see „2.1.4 Type Code“). At mains voltage ≥460V multiply the nominal current with factor 0,86. These units can be used with one or more braking modules. For more informations cantact KEB. Chapter...
Page 39
Password Structure Operation ANTRIEBSTECHNIK The KEB COMBIVERT is provided with extensive password protection. The different 4.2 Password passwords are used to Structure - change the operating mode - set a write protection - activate the Service-Mode - switch to the Drive-Mode...
Page 44
The given tolerances (see parameter description) refer to the respective maximum values with the dimensioning KEB COMBIVERT: Motor = 1:1. Dependent on the data from the motor manufacturer, larger tolerances at the torque displays are possible, due to the usual variations in the machine parameters and temperature drifts.
Page 49
The maximum torque of the drive is limited by the following: – Dimensioning KEB COMBIVERT – Motor If KEB COMIBVERT is dimensioned too small the torque is automatically limited due to a motor current which is too low. – Programming the Motor Parameters CP.25 - CP.30 Dependent on the adjusted motor data a speed-dependent limit curve (see below) is set.
Drive-Mode Operation ANTRIEBSTECHNIK 4.4 Drive-Mode The Drive-Mode is a special operating mode of the KEB COMBIVERT. It allows an easy manual start-up. To activate the Drive-Mode enter the password „500“ in ‘CP.0’ or ‘ud.0’. Following settings are possible: – Stop / Start / Run 4.4.1 Adjustment...
Parameter ANTRIEBSTECHNIK The frequency inverter KEB COMBIVERT F4-C contains 14 fixed and one free-to- Parameter define parameter group. We have already learned about the free-to-define group (CP). In the fixed parameter groups the parameters are combined function-related. 5.1 Parameter 5.1.1 Parameter Groups Pic.
Page 97
Software Software This parameter serves to identify the software that is used on the control by means of KEB COMBIVIS. The configuration is done automatically when COMBIVIS is called and the inverter is connected. In. 7 Serial number / date 2C07h In.
6.2 Analog In- and Outputs 6.2.1 Brief Description The KEB COMBIVERT F4-F incorporates one differential voltage input for setpoint setting (REF1 ±), one programmable differential voltage input (REF2 ±) and two programmable analog outputs (A1 / A2). Depending on the analog input or output signal function, offsett and gain can be adjusted.
6.2.6 Analog Outputs The KEB COMBIVERT F4-F has two programmable analog outputs. Parameters An.14 and An.18 allow the selection of one size each which is given out at the control terminal strip X2. By means of the characteristic amplifier the analog signals can be adapted to the requirements.
ANTRIEBSTECHNIK 6.3 Digital In- and Outputs 6.3.1 Brief Description The KEB COMBIVERT F4-F has 7 external digital inputs, 6 of these inputs are programmable (I1...I6). In addition to that the unit has 4 internal programmable Digital Inputs inputs (IA...ID), which are directly linked with the internal outputs.
Functional Description Digital In- and Outputs The KEB COMBIVERT F4-F has - 2 transistor outputs Out D1 terminal X2.8 Out D1 terminal X2.9 - 1 relay output Out3 terminal X2.20/ X1.21/ X1.22(RLA, RLB, RLC) - 4 internal outputs OUT A...D (firmly connected with the inputs A...ID) For the switching of the digital outputs you can select up to 8 conditions from the 33 condtions available.
6.4.1 Brief Description The setpoint values of the KEB COMBIVERT F4-F can be adjusted analog (REF1 (REF2) as well as digital. The AUX-function offers the possibility to add an analog setpoint to other setpoint settings or to use it as amplification factor for speed controller and torque limits.
Page 137
Functional Description ANTRIEBSTECHNIK Setpoint values To adjust a speed setpoint the KEB COMBIVERT F4-F provides two analog setpoint values (REF1 +/- and REF2 +/-) and three digital setpoint values (parameter SP.1, parameter SP .2 and the motor potentiometer function). The analog setpoint values are adjusted by way of REF1 +/- or REF2 +/-. Internally Analog setpoints: the setpoint signals on REF1 change to REF-internal and on REF2 to AUX-internal.
6.4.5 Ramp Generator The frequency inverter KEB COMBIVERT F4-F offers the possibility to display the adjusted setpoint speed before and after the ramp generator. The setpoint speed before the ramp generator is indicated in parameter ru.20 and the setpoint speed after the ramp generator is shown in parameter ru.4.
[CS. 7] generatoric [CS. 9] • If the KEB COMBIVERT is dimensioned too small to operate the current that is necessary for the required torque, then the maximum torque is limited automatically. • From the motor parameters a speed-dependent torque characteristic is calculated.
Attention! the protective functions refer exclusively to software functions, which possibly may not respond in case of a defective unit. The KEB COMBIVERT allows the thermal monitoring of the motor. For that the ther- 6.6.1 Thermal Motor mal contact or temperature sensor is connected to the terminals OH/OH of the power Protection stage.
ANTRIEBSTECHNIK 6.7 Parameter Sets The KEB COMBIVERT comprises 8 parameter sets (0…7), i.e. all programmable parameters exist 8-times in the inverter and can be assigned independent of each other with different values. Thus it is possible to approach 8 different positions in the positioning module.
Functional Description ANTRIEBSTECHNIK 6.8 Special The KEB COMBIVERT F4-F offers the possibility of controlling a holding brake. To activate the brake control an external digital output must be assigned with the function Functions (do.1…do.8 = value „32“). The adaption of the release and delay time to the employed brake is done with LE.67 and LE.68.
The control is activated via the transistor output (do.1...do.8 value „34“ see „digital outputs“ chapter 6.3.10) of the KEB COMBIVERT. Attention! Don’t use relay output! Temperature switching time The temperature switching time defines the cycle time for the output. This time can (LE.70)
Encoder Interface Functional Desription ANTRIEBSTECHNIK The KEB COMBIVERT F4-F supports two from each other separated encoder 6.9 Encoder Interface channels. Channel 1 (X4) • is an incremental encoder input for sine-wave 1Vss- or rectangular signals Channel 2 (X5) • is an incremental encoder input and/or output for rectangular singals 6.9.1 Designs...
Functional Description Encoder Interface 6.9.2 Encoder The encoder interface 1 is the connection for the speed feedback of the KEB COMBIVERT F4-F, which is imperative for the entire control (current control, too). Interface Channel 1 Fig. 6.9.2 Encoder interface channel 1 (X4)
Positioning Module Functional Description ANTRIEBSTECHNIK The KEB COMBIVERT F4-F permits the storing and the position-controlled approach 6.11 Positioning of up to 8 positions. The position setting is based on the parameter set programming, Module at that one position can be deposited in each parameter set.
The following example was recorded with a COMBIVERT S4, but it also corresponds to a COMBIVERT F4-F: Fig. 6.11.16 Recording of a drive profile KEB-Antriebstechnik (R) COMBIVIS (R) Inverter scope KEB-Antriebstechnik (R) COMBIVIS (R) Inverter scope CH A:Inv 1 ru01 Actual speed 1000rpm/DIV...
Preparatory Measures Start-up ANTRIEBSTECHNIK The following chapter is intended for everybody who has no experience with the KEB 7. Start-up frequency inverters. It shall allow a correct entering into this field. But because of the complex application possibilities we must restrict ourselves to explaining the start-up 7.1 Preparatory...
Initial Start-up ANTRIEBSTECHNIK 7.2 Initial Start-up After all initial measures are done the KEB COMBIVERT F4 can be switched on. For the controlled initial start-up of KEB COMBIVERT F4-F do the following: 7.2.1 Start-up (controlled) Switch off control release (term. X2.1) ⇒...
Error messages are always represented by an „E“ and the corresponding error in the 9.1.2 Error Messages display of KEB COMBIVERT. In the following the displayed indications and their causes and their Cause are described. Undervoltage Occurs when the DC-link voltage drops below the permissible value.
KEB COMBIVERT must be observed. Different braking resistors are available for the KEB COMBIVERT. Please refer to the next page for the corresponding formula and restrictions (valid range) 1.
Page 265
Braking time DEC The braking time DEC is adjusted at the frequency inverter. If it is chosen too small the KEB COMBIVERT switches off automatically and the error message OP or OC appears. The approximate braking time can be determined according to following formulae.
Network Hardware Networks ANTRIEBSTECHNIK The KEB COMBIVERT F4 can be easily integrated into different networks. For that 11. Networks the inverter is fitted with an operator or interface that corresponds to the bus system. Following hardware components are available: 11.1 Network –...
IBS cycle. After switching on the loop-operating voltage the inverter is adjusted to the fastest possible transmission rate via the internal, serial KEB-DIN66019 protocol. For that the application password (ud.01=440) as well as the baud rate (ud.07) and the inverter address (ud.06=1) are automatically adjusted.