KEB COMBIVERT R6-S Applications Manual page 113

Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

Input-coded set source
with input-coded set source
-
maximally 7 of the internal or external inputs may be programmed to set source (0...7 sets), in order to avoid
set source errors.
-
the lowest of the selected inputs has priority at Fr.02 = „3"
(ST>RST>R>F>I1>I2>I3>I4>IA>IB>IC>ID)
-
the highest of the selected inputs has priority at Fr.02 = „4"
(ID>IC>IB>IA>I4>I3>I2>I1>R>F>RST>ST)
Example 2: set 0...5 shall be selected with 5 inputs (I1, I2, I3, IB and ID)
1.)
Set parameter Fr.07 to value „2672"
2.)
Set Fr.02 to value „3" (set source input-coded via terminal strip)
Id
IB
I3
0
0
0
0
0
0
0
0
0
0
0
3
0
4
0
5
0
0
5
0
3
5
0
3
Reset to set 0 / input selection (Fr.11)
Parameter Fr.11 defines an input, independent of the actual parameter set it can be switched in parameter set
0. This function is only active at Fr.02 = 2...4
-
at static input assignment the inverter remains in set 0, as long as the input is set.
-
at slope-triggered inputs set 0 is activated with the first slope. With the second slope the activated pa-
rameter set by the other inputs is selected again.
© KEB, 2008-02
COMBIVERT R6-S
I2
I1
Set
Set
Fr.02 =
3
4
0
0
0
0
0
1
1
1
2
0
2
2
0
0
3
3
0
0
4
4
0
0
5
5
0
0
3
5
0
1
1
5
Parameter sets
ID
IB
I3
I2
I1
Set
5
Set
4
Set
3
Set
2
Set
1
Set
0
3
10
Page3.7 - 9