3.2 Operating and appliance data
The parameter groups „ru", „In" and „SY" are described in this chapter. They serve for operational monitoring,
error analysis and evaluation as well as for unit identification.
3.2.1 Overview of the ru parameters
The ru parameter group displays the multimeter of the inverter. Here voltages, currents etc. are displayed, with
those a statement about the actual operating condition of the inverter can be made. Especially during the start-
up or error search at the unit this can be a great help. Following parameters are available:
ru.00
inverter state
ru.03
actual line frequency
ru.08
AC phase current L1
ru.09
AC phase current L2
ru.10
AC phase current L3
ru.11
input voltage
ru.13
act. DC utilization
ru.14
peak DC utilization
ru.15
DC current
ru.16
peak DC current
ru.17
AC current
ru.18
ref. DC voltage
ru.19
DC voltage
ru.20
peak DC voltage
ru.21
input terminal state
ru.22
internal input state
ru.23
output condition state
ru.24
state of output flags
ru.25
output terminal state
ru.26
active parameter set
ru.33
ANOUT1 pre ampl. display
ru.34
ANOUT1 post ampl. display
ru.38
heat sink temperature
ru.39
Overload integrator (E.OL)
ru.40
power on counter
ru.41
modulation on counter
ru.43
timer 1 display
ru. 44
timer 2 display
ru.46
external temperature
ru.68
rated DC voltage
ru.80
digital outputstatus
ru.81
active power
ru.82
total regen
ru.83
total motor
ru.84
total net
ru.85
actual net
© KEB, 2008-02
COMBIVERT R6-S