Parameter sets
3.7.6 Select parameter sets
Picture 3.7.6 Principle of the parameter set selection
Set selection deac-
tivated
set 0 always active
Fr.03 Parameter set lock
Set 0...7 (value 0...255)
Fr.02 Parameter set source
As seen in picture 3.7.6 Fr.02 determines, whether the parameter set selection is done or switched off via key-
board/bus (Fr.04) terminal strip or via control word (SY.43/ 50). The selection is activated by pressing "Enter".
Value Function
0
Set source deactivated; set 0 always active
1
Set source via keyboard/bus with Fr.04
2
Set source binary-coded via terminal strip
Set source input-coded via terminal strip
3
Priority: ST>RST>R>F>I1>I2>I3>I4>IA>IB>IC>ID
Set source input-coded via terminal strip
4
Priority: ID>IC>IB>IA>I4>I3>I2>I1>R>F>RST>ST
5
Set source via control word SY.43 / 50
Page3.7 - 6
2
2
2
digital
Fr.04 with
Terminal strip
Keyboard/bus
binary-coded
Fr.02: Parameter set source
COMBIVERT R6-S
1
0
2
7
6
5
4
3
2
Terminal strip
input-coded
ST>RST>...>ID
2 3
4
1
5
0
Fr.2
Parameter set 0...7
Is
yes
selected set
locked ?
no
Actual parameter set
1
7
6
5
4
3
2
1
Terminal strip
input-coded
ID>IC>...>ST
ATTENTION! The valence at Fr.02
= 2...4 is generally ID > IC > ...>ST.
The sequence mentioned above
refers to the priority.
Error message
E.SEt
SY.50 with
control word
(only bus)
© KEB, 2008-02