Special functions
Timer reset condition (LE.20 / LE.25)
The conditions when the timer is reset additionally to the inputs can be defined in accordance with the following
table. The individual conditions are OR-operated.
Bit No.
Decimal value condition
0
1
2
3
4
Comparison level 0...7 (LE.00...LE.07)
LE.00...LE.07 define the level for the switching conditions 37 / 38 („timer > level"). If the timer exceeds the
adjusted value the switching condition is set. A level in the range of -10.737.418,24 to 10.737.418,23 can be
adjusted. But only values of 0...655,35 are sensible for the counter.
Page 3.8 - 6
1
Modulation on
2
Modulation off
4
reserved
8
Change of parameter set
16
Power-On-Reset
COMBIVERT R6-S
© KEB, 2008-02