3.2.6 Description of the Sy-Parameters
Parameter
SY.02
Inverter identifier
An unique number is assigned to each inverter type which identifies the COMBIVERT. This value is used
for example by COMBIVIS to load the correct configuration files. SY.02 can be written with the indicated
value (e.g. for identification of download lists).
Parameter
SY.03
Power unit code
On the basis of the power circuit identification the control recognizes the used power circuit, respectively a
change of the power circuit and adjusts certain parameters accordingly. To accept a new P-Id enter positive
values (see chap. 5 „E.Puch").
Parameter
SY.06
Inverter address
In SY.06 can be adjusted, if the COMBIVERT shall be responded via „COMBIVIS" or another control.
Values between 0 and 239 are possible, the default value is 1. If several COMBIVERT are operated on
the bus simultaneously, it is absolutely necessary to assign different addresses to them, since otherwise it
leads to communication failures because several COMBIVERT may answer at the same time. The descrip-
tion of the DIN 66019II protocol (C0.F5.01I-K001) contains further information to this.
Parameter
SY.07
Baud rate ext. bus / PC
Following values for the baud rate of the serial interface are possible:
Parameter value
3 (default)
If the value for the baud rate is changed via the serial interface, it can be changed again only by the key-
board or after adapting the baud rate of the master, as no communication is possible with different baud
rates of master and slave.
Should problems occur at the data transmission choose a transmission rate of maximal 38,4 Baud.
Parameter
SY.09
HSP5 watchdog time
The HSP5 watchdog function monitors the communication of the HSP5 interface (control card - operator;
or control card - PC). After expiration of an adjustable time (0,01...10 s) without incoming telegrams, the
response adjusted in Pn.5 is triggered. The value „off" deactivates the function.
© KEB, 2008-02
Addr.
0002h
Addr.
0003h
Addr.
0006h
Addr.
0007h
Baud rate
0
1,2 KBaud
1
2,4 KBaud
2
4,8 KBaud
9,6 kBaud
4
19,2 kBaud
5
38,4 kBaud
6
55,5 kBaud
Addr.
0009h
COMBIVERT R6-S
Operating and appliance data
R
PG E
Min. value
rw
-
-
4000
R
PG E
Min. value
rw
-
+
0
R
PG E
Min. value
rw
-
+
0
R
PG E
Min. value
rw
-
+
0
R
PG E
Min. value
rw
-
+
0 (off)
Max. value
Res.
[?]
4002
1
-
Max. value
Res.
[?]
32767
1
-
Max. value
Res.
[?]
239
1
-
Max. value
Res.
[?]
6
1
-
Max. value
Res.
[?]
10,00
0,01
s
Page 3.2 - 15
Default
-
Default
-
Default
1
3
Default
3
10
Default
0 (off)