Parameter
ru.80
Digital output state
With do.51 the digital output signals can be assigned to the hardware outputs (see chapter 7.3.). This para-
meter displays the digital output state of the output signals in accordance with the following table. If several
outputs are set, the sum of the decimal values is displayed.
Bit
0
1
2
3
4
5
6
7
Parameter
ru.81
Actual power
ru.81 displays the actual power of the COMBIVERT R6-S. Motor power is displayed with positive values,
generatoric power is displayed with negative values.
Parameter
ru.82
Total regen
Counter for the regeneratoric electric work to the mains.
Parameter
ru.83
Total motor
Counter for the supplied electrical work from the mains.
Parameter
ru.84
Total net
Display of the difference between supplied and regeneratoric work. The result is displayed right sign and is
depending on the faulty wiring.
Parameter
ru.85
Actual net
Display of the actual net.
© KEB, 2008-02
COMBIVERT R6-S
Addr.
R
0250h
ro
Decimal value Output
1
O1 (transistor output 1)
2
O2 (transistor output 2)
4
R1 (relay RLA,RLB,RLC)
8
R2 (relay FLA,FLB,FLC)
16
OA (internal output A)
32
OB (internal output B)
64
OC (internal output C)
128
OD (internal output D)
Addr.
R
0251h
ro
Addr.
R
0252h
rw
Addr.
R
0253h
rw
Addr.
R
0254h
rw
Addr.
R
0255h
ro
Operating and appliance data
PG E
Min. value
Max. value
-
-
0
PG E
Min. value
Max. value
-
-
-3200,0
PG E
Min. value
Max. value
-
-
0
2147483647
PG E
Min. value
Max. value
-
-
0
2147483647
PG E
Min. value
Max. value
-
-
0
2147483647
PG E
Min. value
Max. value
-
-
0,00
Res.
[?]
255
1
-
Terminal
X2A.19
X2A.20
X2A.24...26
X2A.27...29
no
no
no
no
Res.
[?]
3200,0
0,1
kW
Res.
[?]
1
kWh
Res.
[?]
1
kWh
Res.
[?]
1
kWh
Res.
[?]
655,35
0,01
kVA