3.2.4 Description of the ru parameters
Legend:
Addr.
= Address
PG
= programmable
E
= Enter
R
= right
Min. value
= Min. value
Max. value = Max. value
Res.
= Resolution
Default
= Default value
[?]
= Unity
Parameter
ru.00
Inverter state
The inverter state displays the actual operating condition of the regenerative unit. The actual error message
is displayed in error case, even if the display is already reset by ENTER (error LED in the operator is still
flashing). Status messages and information about the cause and removal are described in chapter 5 „Error
diagnosis".
Parameter
ru.03
Actual line frequency
The actual line frequency is determined during the initialization phase after switching on. Slowly changes of
the line frequency during the operation are recognized and displayed in ru.03. If the COMBIVERT R6-S is in
„netof", ru.03 displays the actual regenerative frequency.
Positive values mean a clockwise rotating field and negative values an anti-clockwise rotating field.
Parameter
ru.08
AC current L1
ru.09
AC current L2
ru.10
AC current L3
Display of the actual input current of the respective phase.
Parameter
ru.11
Input voltage
Display of the actual mains voltage
© KEB, 2008-02
+
-
+
-
ro
rw
KB = keyboard
Addr.
0200h
Addr.
0203h
Addr.
0208h
0209h
020Ah
Addr.
020Bh
COMBIVERT R6-S
Operating and appliance data
= programmable
= non-programmable
= yes
= no
= read-only
= reading and writing
R
PG E
Min. value
ro
-
-
0
R
PG E
Min. value
ro
-
-
-320.00
R
PG E
Min. value
ro
-
-
0,0
R
PG E
Min. value
ro
-
-
0
Max. value
Res.
[?]
255
1
-
Max. value
Res.
[?]
320.00
0.01
Hz
Max. value
Res.
[?]
6553,5
0,1
A
Max. value
Res.
[?]
1000
1
V
Page 3.2 - 5
3
Default
0
Default
-
10
Default
0,0