Operating and appliance data
Parameter
In.25
Error diagnosis
Shows the last errors that occurred (in the sets 0...7). The oldest error is in set 7. A new error is stored in
set 0. All other errors are shifted to the next parameter. The oldest error is not applicable. The display of the
error occurs in the highest word (Bit 12...15).
A difference time is determined between errors of the same type (e.g. double OC). This time is stored in the
three low-order words. The display occurs in hexadecimal code.
Example:
The following values are displayed:
Set 0:
Set 1:
Set 2:
Set 3:
Set 4-7:
Explanati-
The error that occurs last is stored in set 0. In the table the highest hex-value „3" indicates
on:
error E.OP (overvoltage).
Before it error E.OL (set 1=2xxx) occurs. Since the errors are of different types, no difference
time was stored.
Error E.OH is stored in set 2 and 3. Since the errors are of the same type, a diffenrence time
(here „023 ") is stored in the three low-order words of set 2. The value of 23 hexadecimal
corresponds decimal to a difference time of 35 minutes.
No errors are stored in set 4...7.
Parameter
In.26 E.OC error counter
In.27 E.OL error counter
In.28 E.OP error counter
In.29 E.OH error counter
In.30 E.OHI error counter
The error counters (for E.OC, E.OL, E.OP, E.OH, E.OHI) specify the total number of errors of each error
type.
Page 3.2 - 14
COMBIVERT R6-S
Addr.
R
PG E
0E19h
ro
+
Error
Difference time
Bit
Bit
Bit
15...12
11...8 7...4 3...0
X
0
0
X
0
0
X
:
:
X
F
F
X
F
F
0
X
X
1
X
X
2
X
X
3
X
X
4
X
X
5
X
X
3000
2000
4023
4000
0000
Addr.
R
PG E Min. value Max. value Res.
0E1Ah
0E1Bh
0E1Ch
rw
0E1Dh
0E1Eh
Min. value
Max. value
-
0
65535
Bit
Value
0
0 min.
1
1 min.
:
:
E
4094 min.
F
> 4095 min.
X
no error
X
E.OC
X
E.OL
X
E.OP
X
E.OH
X
E.OHI
-
-
0
65535
Res.
[?]
Default
1
-
0
[?]
Default
1
-
0
© KEB, 2008-02