KEB COMBIVERT R6-S Applications Manual page 127

Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

3.9.4 Display norm
KEB COMBIVERT offers the user the possibility to define the own standardizations in the CP mode. Parame-
ters ud.18...20 serve as conversion, ud.21 serves as specification of the calculation method, decimal places,
as well as the displayed unity in KEB COMBIVIS.
3.9.4 Define own standardizations
Default
Inverted
For the "selected parameter" either "non-standardized value" or "standardized value/resolution" is used !
ud.18 Divisor display norm
Adjusts the divisor in the range of ±32767 (default 1). The parameter is set-programmable.
ud.19 Multiplier display norm
Adjusts the multiplier in the range of ±32767 (default 1). The parameter is set-programmable.
ud.20 Offset display norm
Adjusts the offset in the range of ±32767 (default 0). The parameter is set-programmable.
ud.21 Control display norm
ud.21 adjusts the calculation mode, decimal places as well as the displayed unity in KEB COMBIVIS. The pa-
rameter is bit-coded and set-programmable. The parameter can be adjusted in the range of 0...1791.
© KEB, 2008-02
ud.19 multiplier
± 32767
CP.xx = (selected parameter + ud.20) x
ud.20 offset
± 32767
ud.19 multiplier
± 32767
CP.xx =
(selected parameter + ud.20) x ud.18
ud.20 offset
± 32767
COMBIVERT R6-S
Define CP-Parameters
ud.19 x unit
ud.18
ud.18 divisor
± 32767
ud.19 x unit
ud.18 divisor
± 32767
ud.21 ctrl. display norm
0...1791
Page 3.9 - 7
3
10

Advertisement

Table of Contents
loading

Table of Contents