DESCRIPTION Of THE TERMINALS
6.3.6 fieldbus interface X6C
The type code (=>
COMBIVERT P6.
6.3.6.1 Profibus DP
The connection is described in the installation instruction (8.021). This can be down-
loaded from www.profibus.com.
Socket D-SUb-9
PIN
Housing
LED
LD5 LD6
LD5
LD6
Figure 53:
PROFIBUS DP interface
6.3.6.2 CAN-Bus
SubD-9 connector
(male)
Figure 54:
CAN-Bus interface
6.3.6.3 Further bus systems
Further bus systems are described in separate manuals.
70
„2.5 Type
Signal
Description
1
–
Reserved
2
–
Reserved
3
RxD/TxD-P
Transmit/receive signal P
4
–
Reserved
5
DGND
Data reference potential
6
VP
Supply voltage for terminating resistor
7
–
Reserved
8
RxD/TxD-N
Transmit/receive signal N
9
–
Reserved
–
High-resistance earthed
Signal
Light pattern
Ready
Data
PIN
Signal
1
Reserved
2
CAN_L
3
CAN_GND
4
Reserved
5
CAN_SHLD
6
GND
7
CAN_H
8
Reserved
9
CAN_V+
Housing
–
code") shows the fieldbus interface that is installed in
Meaning
On
Ready for operation
Off
Not ready for operation
On
Data are transmitted by the PROFIBUS
Off
No data transmission
Description
Not connected here
CAN-Bus signal dominant low
Not connected here
Not connected here
Capacitively earthed
Not connected here
CAN-Bus signal dominant high
Not connected here
Not connected here
Resistively / capacitively earthed