Operating and appliance data
Parameter
ru.39
OL counter display
In order to prevent „E.OL" - errors by overload (load reduction in due time), the internal count of the OL
counter can be made visible with this display. At 100% the COMBIVERT switches off with error „E.OL". The
error can be reset only after a cooling time (blinking display „E.nOL").
Parameter
ru.40
Power on counter
The power on counter displays the time the inverter was switched on. The displayed value comprises all
operating phases. On reaching the maximum value (approx. 7.5 years) the indication remains on the maxi-
mum value.
Parameter
ru.41 Modulation on counter
The modulation on counter displays the time the COMBIVERT was active (power modules controlled). On
reaching the maximum value (approx. 7.5 years) the indication remains on the maximum value.
Parameter
ru.43
Timer 1 display
The count of the free-programmable timer 1 is displayed. The display is done either in seconds, in hours
or in slopes/ 100 (see LE.21). The counter can be adjusted to any chosen value by keyboard or bus. The
programming of the counter is done with parameters LE.17...LE.21.
Parameter
ru.44
Timer 2 display
The count of the free-programmable timer 2 is displayed. The display is done either in seconds, in hours
or in slopes/100 (see LE.26). The counter can be adjusted to any chosen value by keyboard or bus. The
programming of the counter is done with parameters LE.22...LE.26.
Parameter
ru.46
External temperature
Overtemperature switch of the commutation throttle. Precondition for this function is a special power circuit.
The temperature detection is connected to the terminals T1/T2.
0:
T1/T2 closed
255:
T1/T2 open
Parameter
ru.68
Rated DC voltage
This parameter displays the rated DC voltage automatically determined by the inverter. The value is measured
at switch-on.
Page 3.2 - 10
COMBIVERT R6-S
Addr.
R
0227h
ro
Addr.
R
0228h
rw
Addr.
R
0229h
rw
Addr.
R
022Bh
rw
Addr.
R
022Ch
rw
Addr.
R
022Eh
ro
252:
Addr.
R
0244h
ro
PG E
Min. value
Max. value
-
-
0
PG E
Min. value
Max. value
-
-
0
PG E
Min. value
Max. value
-
-
0
PG E
Min. value
Max. value
-
-
0
PG E
Min. value
Max. value
-
-
0
PG E
Min. value
Max. value
-
-
0
power unit not ready
PG E
Min. value
-
-
0
Res.
[?]
100
1
%
Res.
[?]
65535
1
h
Res.
[?]
65535
1
h
Res.
[?]
655,35
0,01
-
Res.
[?]
655,35
0,01
-
Res.
[?]
255
1
-
Max. value
Res.
[?] Default
1000
1
V
© KEB, 2008-02
Default
-
Default
-
Default
-
Default
-
Default
-
Default
-
-

Advertisement

Table of Contents
loading

Table of Contents