3.9 Define CP-Parameters
If the development stage of a machine is completed, usually only a few parameters are required to adjust or
control the COMBIVERT. In order to simplify the handling and end-user documentation, as well as the security
against unauthorized access, there is the possibility to create an own user interface, the CP-Parameters. 37
parameters (CP.00...CP.36) are available for this, 36 parameters (CP.01...CP.36) can be assigned free.
3.9.1 Overview
Picture 3.9.1
Application mode
ud.15
Address
1
Address
2
Address
36
ud.15 determines the CP-Parameter to be processed. With ud.16 and ud.17 the CP-Parameter is defined by its
address, the respective set and the display norm. Dependent on the adjusted password (CP.00 or ud.01)
- the adjusted parameter is directly displayed in the service mode
- the adjusted parameter is displayed as CP-Parameter in the CP mode
Parameter CP.00 is not configurable, it always includes the password input. ud.01 is used for password input if
the inverter is in application or service mode.
Parameters which are not permissible as CP-Parameters (e.g. ud.15 ... 17 and Fr.1) are confirmed with "data
invalid". Input of an invalid parameter address switches the parameter to "oFF" (-1). The corresponding CP-
Parameter is not displayed in this setting.
© KEB, 2008-02
COMBIVERT R6-S
Definition structure
440
Service mode
ud.16
ru.3
Set / norm
ud.17
ud.16
ru. 3
Set / norm
ud.17
ud.16
An.32
Set / norm
ud.17
Define CP-Parameters
Password
CP.0 / ud.1
330
200
100
Reading /
read-
writing
only
CP mode
CP.1
CP.2
CP.36
500
Drive
mode
Page 3.9 - 3
3
10