Sign In
Upload
Manuals
Brands
KEB Manuals
Power Supply
combivert R6-S
KEB combivert R6-S Manuals
Manuals and User Guides for KEB combivert R6-S. We have
6
KEB combivert R6-S manuals available for free PDF download: Applications Manual, Instruction Manual
KEB combivert R6-S Applications Manual (168 pages)
Brand:
KEB
| Category:
Inverter
| Size: 6.36 MB
Table of Contents
Introduction
3
Introduction
2
Table of Contents
3
Introduction
4
Use of Power Supply and Regenerative Units
11
Functional Principle
12
Part Code
13
Hardware
15
Control Board 1B.R6
17
Control Boards
17
Control Board 2B.R6
18
Control Terminal Strip X2A
19
Activation of the Self-Holding X2C
21
HSP5 Operator Interface X4B
21
Synchronization Line X2B
21
Connection for Precharging X1B
22
Connection of the Control Release of the Connected Inverter
22
Operation
25
Fundamentals
25
Parameters, Parameter Groups, Parameter Sets
25
Adjustment of Parameter Values
26
Selection of a Parameter
26
Acknowledge of Feedbacks
27
ENTER Parameters
27
Not Set-Programmable Parameters
27
Reset of Error Messages
27
Reset of Peak Values
27
Password Structure
29
Password Levels
30
Passwords
32
Network Components
35
Functions
35
Parameter Overview
40
Functions
41
Analog Outputs
67
Digital In- and Outputs
72
Digital Inputs in PNP Control (DI.00)
74
Set Digital Inputs Per Software (DI.01, DI.02)
74
Input Terminal State (Ru.21), Internal Input State (Ru.22)
75
Digital Noise Filter (DI.03)
76
Input Trigger (DI.05)
76
Invert the Inputs (DI.04)
76
Strobe-Dependent Inputs (DI.06, DI.07, DI.08)
76
Assignment of the Inputs
78
Reset / Input Selection (DI.09) and Neg. Slope for Reset Inputs (DI.10)
78
Software-ST and Locking of the Control Release
80
Conditions (Do.00
83
AND/OR Connection of the Conditions (Do.24)
85
Operating Mode
91
Invert Conditions for Flags 0
85
Selection of the Conditions for Flags 0
85
Protective Functions
96
Error and Warning Messages
97
Undervoltage
98
Overvoltage
98
Overcurrent
98
Overload
99
Inverter Overtemperature
99
External Fault
99
Bus Error
100
Set Selection Error
100
Hardware Error
100
Regeneration Error
101
Response to Malfunction Messages
101
Selection of the Response
101
General Fault Reset (Pn.15)
102
Automatic Restart
103
Undervoltage Error (E.UP)
103
Overvoltage Error (E.OP)
103
Overcurrent Error (E.OC)
103
Malfunction Messages and Pre-Warnings
103
Special Functions
104
Parameter Sets
106
Indirect and Direct Set-Addressing
107
Not Set-Programmable Parameters
107
Security Parameters
107
Copy Parameter Sets Via Bus (Fr.01, Fr.09)
109
Locking of Parameter Sets
114
Parameter Set Activation Delay/ Deactivation Delay (Fr.05, Fr.06 )
114
Start-Up
133
Installation and Connection
133
Safety Instructions
134
Start-Up
138
Project Design
145
Error Assistance
147
Troubleshooting
147
Status Messages
147
Warning Messages
149
Annex
151
Project Design
153
Advertisement
KEB combivert R6-S Instruction Manual (56 pages)
Power Supply and Regenerative Unit
Brand:
KEB
| Category:
Power Supply
| Size: 3.69 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Preface
5
Product Description
5
Validity and Liability
6
Copyright
6
Specified Application
7
Standard Operation
7
Abnormal Operation
7
Unit Identification
8
2 Safety Instructions
9
General Instructions
9
Transport, Storage and Installation
9
Electrical Connection
10
EMC Instructions
14
EMC Conform Installation
14
3 Technical Data
15
Overload (OL) Function
16
Operating Conditions
16
Accessories
18
Options
18
Ferrite Rings
18
Dimensions and Weights
19
Dimensions Air Cooling System Mounted Version
19
Commutation Reactor/Mains Choke
20
Radio Interference Filter (Side-Mounted)
21
Synchronization Unit
21
4 Installation
22
EMC-Compatible Control Cabinet Installation
22
Installation Instructions
22
Connection of the COMBIVERT R6
23
General Description of Inverter Input Terminals
23
Connection Terminals of the Power Circuit
25
External Fan Power Supply
26
Connections of the Control Board
27
Connection of the Synchronization Unit
27
Connection Power Unit R6-S
28
Power Supply And Regenerative Operation At Inverter Current ≤ Current Of One
28
Combivert R6-S
28
Power Supply And Regenerative Operation At Inverter Currents ≤ Current Of One
29
Combivert R6-S
29
Power Supply and Regenerative Operation at Parallel Operation of up to Three R6-S
30
Regenerative Operation at Parallel Operation of up to Three R6-S with Decoupling Diodes
33
Connection of the Control Board Version S
35
Assignment of the Control Terminal Strip X2A
35
Assignment of the Socket X2B
36
Assignment of the Terminal Block X2C
36
Wiring Example
37
Operator
38
5 Operation of the Unit
39
Operation with PC und System Software COMBIVIS
39
Switch-On Procedure
39
Parameter Summary
40
Monitoring and Analysis Parameters
41
AC Current L1
42
AC Current L2
42
AC Current L3
42
CP.01 Status Display
42
CP.02 Actual Line Frequency - 0.1 Hz
42
CP.06 Act.DC Utilization - 1
42
Peak DC Utilization
42
DC Current
43
DC Voltage
43
OL Counter Display
43
Peak DC Voltage
43
Peak Value
43
Power Module Temperature
43
0.01 Kva
44
CP.14 Total Regen
44
CP.15 Total Motor
44
CP.16 Total Net
44
CP.17 Actual Net
44
Special Adjustments
45
ANOUT 1 Gain
45
Comparison Level 0
45
CP.20 General Fault Reset 0
45
Last Error
46
Last Error -1
46
Last Error -2
46
Last Error -3
46
Last Error -4
46
Last Error -5
46
Last Error -6
46
Last Error -7
46
Software Date
46
Software Version
46
CP.34 Regeneration Level 100
47
A. Appendix A
48
Dimensioning Power Supply and Regenerative Units
48
DC Link Capacitors of KEB Frequency Inverters
49
Decoupling Diodes
51
Assignment
51
Dimensions of the Decoupling Diodes
52
KEB combivert R6-S Instruction Manual (56 pages)
Power Supply and Regenerative Unit
Brand:
KEB
| Category:
Power Supply
| Size: 3.14 MB
Table of Contents
Table of Contents
3
Introduction
5
Preface
5
Product Description
5
Validity and Liability
6
Copyright
6
Specified Application
7
Standard Operation
7
Abnormal Operation
7
Unit Identification
8
Safety Instructions
9
General Instructions
9
Transport, Storage and Installation
9
Electrical Connection
10
EMC Instructions
14
EMC Conform Installation
14
Technical Data
15
Standard Device Size
15
Special Device Peak Power
16
Overload (OL) Function
17
Operating Conditions
18
Accessories
19
Options
19
Dimensions and Weights
20
Combivert R6-S
20
Commutation Reactor
20
Synchronisation Unit
21
Radio Interference Filter (Sub-Mounted)
22
Ferrite Rings
22
Installation
23
EMC-Compatible Control Cabinet Installation
23
Installation Instructions
23
Connection of the COMBIVERT R6
24
General Description of Inverter Input Terminals
24
Connection Terminals of the R6 Power Circuit
26
Terminals Commutation Reactor / Harmonic Filter
28
Connection Power Unit R6-S
29
Power Supply And Regeneration At Inverter Current ≤ Inverter Current Of One
29
Combivert R6-S
29
Power Supply And Regeneration At Inverter Currents ≥Inverter Current Of One
29
Combivert R6-S
30
Regeneration with Decoupling Diodes
31
Regenerative Operation at Parallel Operation of up to Three R6-S with Decoupling Diodes
33
Connection of the Control Board Version S
35
Assignment of the Control Terminal Strip X2A
35
Assignment of the Socket X2B
36
Wiring Example
37
Operator
38
Operation of the Device
39
Operation with PC and System Software COMBIVIS
39
Switch-On Procedure
39
Parameter Summary
40
Monitoring and Analysis Parameters
41
Special Adjustments
44
Annex a
48
Dimension of Power Supply and Regenerative Units
48
DC Link Capacities of KEB Drive Controllers
49
Decoupling Diodes
51
Assignment
51
Dimensions of the Decoupling Diodes
52
Annex B
53
Certification
53
CE-Marking
53
Ul Certification
53
Advertisement
KEB combivert R6-S Instruction Manual (42 pages)
Power Supply and Regeneration Unit
Brand:
KEB
| Category:
Power Supply
| Size: 0.52 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Preface
4
Product Description
4
Specifi Ed Application
5
Standard Operation
5
Abnormal Operation
5
Unit Identifi Cation
5
2 Safety Instructions
6
General Instructions
6
Transport, Storage and Installation
6
Electrical Connection
7
EMC Instructions
10
EMC Conforming Installation
10
3 Technical Data
12
Power Data
12
Operating Environment Specifi Cations
13
Accessories
14
Options
14
Dimensions and Weights
14
Combivert R6-S
14
Commutation Choke
15
HF Sub-Mount Fi Lter
15
Synchronization Cable
15
Ferrite Rings
15
4 Installation
16
EMC-Compatible Control Cabinet Installation
16
Installation Instructions
16
Connection of the COMBIVERT R6
17
Connection Terminals of the Power Circuit
17
Connection Terminals of the Commutation Choke
17
Connection Power Circuit R6-S with Internal Fuses
18
Points for General Consideration
18
Wiring Scheme 'A' with Single Regen Unit
18
Wiring Scheme 'A' with Single Regen Unit and Harmonic Filter
18
Wiring Scheme 'A' with Parallel Regen Units
19
Wiring Scheme 'B' with Single Regen Unit
20
Wiring Scheme 'B' with Parallel Regen Units
21
Sizing for Wiring Scheme a
22
Sizing F5 DC Bus Capacitances
23
Control Connections
24
Assignment of the Control Terminal Strip X2A
24
Assignment of Socket X2B
24
Wiring Example
25
Operator
26
5 Operation of the Unit
27
Keyboard
27
Operation with PC and Programming Software COMBIVIS
27
Turn-On and Operation Procedure
28
Parameter Summary
29
Parameter Description
30
6 Diagnosis and Troubleshooting
34
Status Display: Status and Error Messages
34
Status Messages
34
Error Messages
34
Troubleshooting
35
Troubleshooting Error Messages
35
Troubleshooting Operational Problems
38
Certifi Cation
40
CE Marking
40
UL Marking
40
CSA Marking
40
A.1 Certifi Cation
40
KEB combivert R6-S Instruction Manual (46 pages)
Power Supply and Regenerative Unit
Brand:
KEB
| Category:
Power Supply
| Size: 6.33 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Preface
5
Product Description
5
Figure 1: Block Diagram of the COMBIVERT R6S
6
Validity and Liability
7
Copyright
7
Specified Application
7
Standard Operation
7
Abnormal Operation
8
Unit Identification
8
2 Safety Instructions
9
General Instructions
9
Transport, Storage and Installation
9
Electrical Connection
10
3 Technical Data
14
Overload (OL) Function
15
Figure 2: Overload (OL) Function
15
Operating Conditions
16
Accessories
17
Options
18
Ferrite Rings
19
Dimensions and Weights
20
Dimensions Air Cooling System Mounted Version
20
Figure 3: COMBIVERT R6 with Fan Heat Sink
20
Commutation Reactor / Mains Choke
21
Radio Interference Filter (Side-Mounted)
22
Synchronization Unit
24
Fuse Holder with Cover
25
Figure 8: Fuse Holder
25
4 Installation
26
EMC-Compatible Control Cabinet Installation
26
Installation Instructions
26
Figure 9: EMC-Compatible Control Cabinet Installation
26
Connection of the COMBIVERT R6
27
General Description of Inverter Input Terminals
27
Connection Terminals of the Power Circuit
28
Connection Power Unit R6-S with UL
30
Power Supply and Regenerative Operation at Inverter Current ≤ Inverter Current of One COMBIVERT R6-S with UL
30
Power Supply and Regenerative Operation at Parallel Operation with One Frequency Inverter
31
Power Supply and Regenerative Operation at Parallel Operation with a Second Regene- Rative Unit
31
4.4.4 Brief Description Of The Pre-Charging Sequence
32
Connection of the Control Board Version S
33
Assignment of the Control Terminal Strip X2A
33
Assignment of the Socket X2B
34
Assignment of the Terminal Block X2C
34
Wiring Example
35
5 Operation of the Unit
36
Operation with PC and System Software COMBIVIS 6
36
Switch-On Procedure
36
Parameter Summary
37
Monitoring and Analysis Parameters
38
Special Adjustments
42
A. Appendix A
45
Certification
45
A.1.1 Ce Marking
45
A.1.2 Ul Certification
45
KEB combivert R6-S Instruction Manual (40 pages)
Brand:
KEB
| Category:
Industrial Equipment
| Size: 2.6 MB
Table of Contents
Table of Contents
3
Introduction
4
Preface
4
Product Description
4
Specified Application
5
Standard Operation
5
Abnormal Operation
5
Unit Identification
5
Safety Instructions
6
General Instructions
6
Transport, Storage and Installation
6
Electrical Connection
7
EMC Instructions
10
EMC Conform Installation
10
Technical Data
11
Power Data
11
Operating Conditions
12
Accessories
13
Options
13
Dimensions and Weights
13
Combivert R6-S
13
Commutation Throttle
14
Hf Sub-Mounting Filter
14
Ferrite Rings
14
Installation
15
EMC-Compatible Control Cabinet Installation
15
Installation Instructions
15
Connection of the COMBIVERT R6
16
Connection Terminals of the Power Circuit
16
Connection Terminals of the Commutation Throttle
16
Connection Power Circuit R6-S with Internal Fuses
17
Power Supply And Regenerative Operation At Inverter Current ≤ Current Of One Combivert R6-S
17
Power Supply And Regenrative Operation At Inverter Currents ≤ Current Of One Combivert R6-S
17
Power Supply And Regenrative Operation At Inverter Currents ≥ Current Of One Combivert R6-S
18
Power Supply and Regenerative Operation with Contactor Circuit
19
Regenerative Operation with Decoupling Diodes
20
Power Supply /Regenerative Operation at Parallel Operation of COMBIVERT R6-S with Recovery Contactor
21
Regenerative Operation at Parallel Operation of COMBIVERT R6-S with Decoupling Diodes
22
Connection of the Control Board Version S
23
Assignment of the Control Terminal Strip X2A
23
Assignment of Socket X2B
23
Wiring Example
24
Operator
25
Operation of the Unit
26
Keyboard
26
Operation with PC und System Software COMBIVIS
26
Switch-On Procedure
26
Parameter Summary
28
Password Input
29
Monitoring- and Analysis Parameters
29
Special Adjustments
33
Appendix
36
Dimensioning of Power Supply and Regenerative Units
36
DC Link Capacitors of KEB Frequency Inverters
37
Dimensioning of Decoupling Diodes
37
Advertisement
Related Products
KEB Combivert R6
KEB COMBIVERT R6-N
KEB COMBIVERT R5-C
KEB COMBIVERT 25R6S3R-R00A
KEB COMBIVERT R4-S
KEB COMBIVERT F5
KEB COMBIVERT F5 Servo
KEB COMBIVERT S4
KEB COMBIVERT F0
KEB COMBIVERT F5 Series
KEB Categories
DC Drives
Controller
Control Unit
Inverter
Media Converter
More KEB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL