3.8
Special functions
The following section should facilitate the adjustment and programming of special functions.
3.8.1 Program timer / counter
Two timers are incorporated in the COMBIVERT. As long as one of the adjustable starting conditions (LE.18/
23) or a programmable input (LE.17/ 22) is set, the timer counts until reaching the final range value. If one of the
reset conditions (LE.20/ 25) is met or one programmable input (LE.19/ 24) is set, the timer jumps back to zero.
The clock source and the counting direction is adjusted with LE.21/ 26. It can be counted in seconds, hours or
by a special programmed input for that. The current timer content is displayed in ru.43/44. Switching condition
37/ 38 is set with reaching an adjustable switching level (LE.00...07). It can be used to set an output.
Picture 7.15.4
LE.21 Timer 1 /
I3
Mode
LE.26 Timer 2 /
I4
Mode
© KEB, 2008-02
Timer programming
continues to count
Timer counts up to maximum
value; down to 0, if a condition
of LE.18 is met or an input of
LE.17 is set
ru.43 Timer 1 display
Resetting to zero
continues to count
Timer counts up to maximum
value; down to 0, if a condition
of LE.23 is met or an input of
LE.22 is set
ru.44 Timer 2 display
Reset to zero
COMBIVERT R6-S
Special functions
Is a
reset condition
no
Timer value > level
of LE.20 or LE.19
met ?
LE.0...LE.7 ?
yes
Is a
reset condition
no
Timer value > level
of LE.25 or LE.24
LE.0...LE.7 ?
met ?
yes
no
Switching condition
yes
37 „Timer 1 > Level A"
is being set!
no
Switching condition
yes
38 „Timer 2 > Level A"
is being set!
Page 3.8 - 3