KEB COMBIVERT R6-S Applications Manual page 126

Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

Define CP-Parameters
3.9.3 Example
An user menu with the following features shall be programmed as example:
1.
2.
3.
1.)
2.)
3.)
4.)
Set all other parameters like CP.4 to "off", that there is no display.
The acceptance of values occurs only after power-on reset of the operator.
Page 3.9 - 6
Display of the actual line frequency (ru.03) in the respective set
Setting of a comparison level (LE.00) in set 2
Setting of a comparison level (LE.00) in set 3
ud.15 = 1
ud.16 = 0203h
ud.17 = 256
ud.15 = 2
ud.16 = 0D00h
ud.17 = 4
ud.15 = 3
ud.16 = 0D00h
ud.17 = 8
ud.15 = 4
ud.16 = -1: off
ud.17 = xxx
COMBIVERT R6-S
; CP.01
; Parameter address for ru.03
; Display in the active set
; CP.02
; Parameter address for LE.00
; Setting in set 2
; CP.03
; Parameter address for LE.00
; Setting in set 3
; CP.04
; CP.04 is faded out
; ud.17 is without function
© KEB, 2008-02