General Fault Reset (Pn.15) - KEB COMBIVERT R6-S Applications Manual

Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

Protective functions
The response to the malfunction message limit switch error (hardware or software) and set selection error can
be switched off completely.
Value
6: Function swit-
ched off
For the malfunction „overtemperature commutation choke", there are several additional choices:
Value
0: Error
6: Warning via
digital output
7: no error
For the malfunction „internal overtemperature", there are two response options as well:
Value
6: Warning via
digital output
7: Error deacti-
vated

3.6.2.2 General fault reset (Pn.15)

Functional description „Pn.15 > 0"
a) The first error is reset after a waiting period of approx. 4 seconds.
b) Any further errors that occur within the next hour, will also be reset at the end of the waiting period.
If there are more errors than adjusted in Pn.15 within this hour, the unit can only be reset manually via terminal
strip or via „BUS".
Manual resetting of a fault resets also the „time grid". That means, the next error will automatically reset again
after the waiting period.
Seite 3.6 - 8
Description
the malfunction is ignored, no response of the drive, no message via digital output
possible
Pn.12: Warning OH commutation choke
Description
no auto restart
the temperature is monitored, the inverter does not execute an automatic abnormal stop
during the pre-warning period, the pre-warning message can only be issued via a digital
output. After expiration of the pre-warning period, the inverter goes to error E.doH.
Temperature is not monitored, the error overtemperature is never triggered. No message
via digital output possible.
Pn.16: Internal overtemperature
Description
The monitoring of the internal temperature is active, but the drive does not execute an
automatic abnormal stop. A pre-warning signal can be issued via a digital output.
Monitoring of the internal temperature never triggers an error. A pre-warning signal
does not exist.
COMBIVERT R6-S
Pn.03, Pn.05, Pn.18
© KEB, 2008-02

Advertisement

Table of Contents
loading

Table of Contents