Fault at the hydraulic system
Error/malfunction
Possible cause
Continuous operation of the hydraulic connec-
tions is switched on and operates against
pressure
Dirty hydraulic oil radiator
Hydraulic system
Insufficient V-belt tension
overheats
Malfunctioning fan blade drive
Incorrect hydraulic oil level
Load too high
BA TH412 * 06/2017 * 4512_8_Stoerungen_en.fm
Remedy
Switch off continuous operation of hydraulic
connections
Cleaning
Tensioning the V-belt
Take the machine to a service center
Correct the hydraulic oil level
Reduce the load on the machine, take breaks
Malfunctions 8