5 Operation
Central lubrication system
The central lubrication system automatically lubricates the
lubrication points of the machine.
The LED of the central lubrication system illuminates for
1.5 seconds after switching on the starter to indicate
functional readiness of the controls. It stays lit during the
entire lubrication procedure.
The integrated electronic control unit has a data memory
for saving the times that have been set or that have
elapsed. The time is taken and saved if the starter is
switched off during lubrication or during a break. The
remaining lubrication time or break time is read from the
memory upon switching the starter on again, and
lubrication is resumed where it was interrupted.
NOTICE
Vehicle damage if lubrication points are not lubricated.
► Note the notice on page 7-71.
5-106
Lubrication time control
Fig. 124
Break and lubrication times can be set with the time-
dependent control of the central lubrication system. Break
times are the periods between two lubrication times.