5 Operation
Break times and lubrication times are set with the notched
switches (S and P) in the window of the controls.
To set the time, remove the red frame
motor protective housing of the pump with a flat screw-
driver.
Loosen the four cross-slotted screws.
➥ Remove the cover.
Set the break time P and lubrication time S with a flat
screwdriver.
Install the cover once setting is over.
Setting lubrication times (S)
➥ 1 to 16 minutes (16 notches, 1 minute each)
Setting break times (P)
➥ 0.5 to 8 h (16 notches, 0.5 h each)
5-108
LED (L)
The LEDs signal various operating states of the central
(Fig.
125) on the
lubrication system.
When switching on the ignition:
Both LEDs light up for 1.5 seconds for a self-test.
During the entire lubrication process:
The red LED does not light up.
The green LED lights up continuously.
Should errors occur on the lubrication system:
The red LED flashes.
The green LED does not light up.