Drive Alarm Contents - YASKAWA SI-C3 Technical Manual

Ac drive option cc-link
Hide thumbs Also See for SI-C3:
Table of Contents

Advertisement

10 CC-Link Code Numbers List
Extended Command Code
(Monitor Code) (Hex.)
CPF contents 3
132 (101E)

Drive Alarm Contents

Monitor Code (Hex.)
Alarm contents 1
101F
Alarm contents 2
1020
48
Name
BIT
F
CPF31 [ASIC Code Error]
0
CPF32 [ASIC Startup Error]
1
CPF33 [Watch-dog Eror]
2
CPF34 [Power/Clock Eror]
3 - F
Reserved
Table 10.5 Drive Alarm Contents
Name
BIT
0
Uv [Undervoltage]
1
ov [Overvoltage]
2
oH [Heatsink Overheat]
3
oH2 [External Overheat]
4
oL3 [Overtorque Detection 1]
5
oL4 [Overtorque Detection 2]
6
EF [FWD/REV Run Command Input Error]
7
bb [Baseblock]
8
EF3 [External Fault (Terminal S3)]
9
EF4 [External Fault (Terminal S4)]
A
EF5 [External Fault (Terminal S5)]
B
EF6 [External Fault (Terminal S6)]
C
EF7 [External Fault (Terminal S7)]
D
EF8 [External Fault (Terminal S8)]
E
Reserved
F
oS [Overspeed]
0
dEv [Speed Deviation]
1
PGo [Encoder (PG) Feedback Loss]
2
oPr [Keypad Connection Fault]
3
CE [MEMOBUS/Modbus Communication Error]
4
bUS [Option Communication Error]
5
CALL [Serial Communication Transmission Error]
6
oL1 [Motor Overload]
7
oL2 [Drive Overload]
8
Reserved
9
EF0 [Option Card External Fault]
A
rUn [Motor Switch during Run]
B
Reserved
C
CALL [Serial Communication Transmission Error]
D
UL3 [Undertorque Detection 1]
E
UL4 [Undertorque Detection 2]
F
SE [Modbus Test Mode Error]
Fault Code (U2, U3) (Hex.)
Alarm Code
(MEMOBUS/Modbus Register 07F (Hex.))
YASKAWA SIEP C730600 83E CC-Link Technical Manual
00A0
-
00A1
00A2
00A3
-
-
0001
0002
0003
0004
0005
0006
0007
0008
0009
000A
000B
000C
000D
000E
-
0010
-
0011
0012
0013
0014
0015
0016
0017
0018
-
001A
001B
-
001D
001E
001F
0020

Advertisement

Table of Contents
loading

Table of Contents