Programming Example; Blocks In The Example Project - Siemens SIMATIC FM 351 Installation Manual

Positioning function module
Hide thumbs Also See for SIMATIC FM 351:
Table of Contents

Advertisement

Programming the FM 351
6.5
Introduction
Parameterization
Blocks
6
6-32

Programming Example

On the enclosed diskette you will find a programming example with which
you can test the basic functional features of the FM 351. In this chapter we
describe the required surrounding conditions and the controlling elements.
In this example project special machine data is deposited. If you would like
to test the example program in your own installation, enter your special ma-
chine data.
In the project all blocks must be linked which are required for execution of
the task.
Table 6-9
Block
DB1
FC0
FC1
FC5
FC6
FC8
FC9
FC10
FC11
FC12
FC13
FC100
OB1
OB82
OB100

Blocks in the Example Project

Name
DB_FM
Channel DB
INC_MOD
Incremental mode
REFPT
Set reference point
SNG_FCT
Call single settings
SNG_COM
Call single commands
DIAG_INF
Read diagnostic information
ACT_DAT
Read service or basic operating data
JOG_MODE Jogging
REF_MODE Seek reference point
TG254
Transfer Increment 254
TG253_5
Transfer Increment 255
AUFR_TF
Call the function
CYCL_EXC
Free PLC cycle
I/O_FLT1
Diagnostic interrupt
CRST
Restart