Application Example For Position Measurement Of 12 Axes - Siemens WF 705 Description

Position measuring module
Table of Contents

Advertisement

Operation with SIMATIC S5
3.3

Application Example for Position Measurement of 12 Axes

3.3.1
Initial Start and Restart
OB21
SPRM-A
SEGMENT 1
0000
: JU
PB20
0001
: BE
OB22
SPRM-A
SEGMENT 1
0000
: JU
PB20
0001
: BE
PB20
SPRM-A
SEGMENT 1
0000
: L
KB0
0001
: T
FW 122
0002
: JU
FB100
0003
NAME : ANL-705
0004
DBBG :
DB100
0005
GE1
:
KF+8192
0006
GE2
:
KF+4096
0007
GE3
:
KF+2048
0008
GE4
:
KF+1024
0009
GE5
:
KF+512
000A
GE6
:
KF+256
000B
GE7
:
KF+128
000C
GE8
:
KF+64
000D
GE9
:
KF+32
000E
GE10 :
KF+16
000F
GE11 :
KF+8
0010
GE12 :
KF+4
0011
BAUD :
FW 122
0012
ADR
:
KF+128
0013
FEHL :
F 100.0
0014
:
0015
:
0016
: BE
3 - 10
Number of steps/revolution axis 1
Number of steps/revolution axis 2
Number of steps/revolution axis 3
Number of steps/revolution axis 4
Number of steps/revolution axis 5
Number of steps/revolution axis 6
Number of steps/revolution axis 7
Number of steps/revolution axis 8
Number of steps/revolution axis 9
Number of steps/revolution axis 10
Number of steps/revolution axis 11
Number of steps/revolution axis 12
Read-out all axes at 125 kbaud
©
Siemens AG 1990 All Rights Reserved
11.96
LAE=7
ABS
PAGE 1
LAE=7
ABS
PAGE 1
LAE=23
ABS
PAGE 1
6ZB5 440-0AA02
WF 705 (Description)