4.2 Functions

4.2.1

Configuring Caps Lock

Via the display machine data MD 9009: KEYBOARD_STATE sets the key behavior
of Capslock:
0: SingleShift is active after ramp-up
1: Setting not relevant!
2: CAPSLOCK is active after ramp-up (default setting)
References:
4.2.2

Activating screen darkening

If a screen with high contrast is displayed unchanged for longer than an hour, the
screen must be switched dark (screensaver) in order to protect the TFT display
against so-called "freezing" of the last displayed screen.
Activate using PLC
You can activate the screen darkening with the PLC in DB19.DBB0. The PLC has
priority over the entry in the display machine data.
References:
Activate using the machine data
Via the display machine data MD 9006: DISPLAY_BLACK_TIME is used to specify
the duration (max. 60 minutes), after which the screen is automatically darkened if
no key is pressed on the keyboard.
In this display machine data, the "Screen dark from HMI Embedded" function can
be started with the following entry:
MD 9006
MD 9006
MD 9006
4.2.3

Language selection - Change Language

The HMI software is available in 6 languages as standard:
You can access language selection via the "Language Selection" softkey in the
"Startup" operating area.
Select the first and second languages from the "Language Selection" menu.
During operation, the switchover between the set languages is performed via the
"Change Language" softkey in the "Startup" operating area.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
/FB1/ A2: Various Interface Signals
/FB1/ A2: Various Interface Signals
= 1
< time in minutes, e.g., 1 >
= 60
< time in minutes, e.g., 60 >
= 0
Deactivation of the function (default setting)
Starting Up HMI Embedded (IM2)
4 Functions/Parameterization
IM2/4-37