Access Protection Using Password And Keylock Switch - Siemens SINUMERIK 840D sl Commissioning Manual

Commissioning cnc part 2 (hmi)
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

08/2005

4.1 Access protection using password and keylock switch

Access levels for enabling data areas are implemented in the SINUMERIK 840D sl.
These are subdivided into:
4 password levels for Siemens, machine manufacturer and end user.
4 keyswitch positions for end user.
This provides a multilevel safety concept for controlling access rights.
Access rights
0 to 3 are locked by means of a password and
4 to 7 by means of keyswitch positions.
Table 4-1
Protection
level
0
1
2
3
4
5
6
7
Access features
Protection level 0 provides the greatest number of access rights,
protection level 7 the least.
If certain access rights are granted to a protection level, these protection
rights automatically apply to any higher protection levels.
Conversely, protection rights for a certain protection level can only be
altered from a higher protection level.
Access rights on protection levels 0 to 3 are set as Siemens defaults.
Access rights can be set by querying the current keyswitch positions and
comparing the passwords entered. When a password is entered it
overwrites the access rights of the keyswitch position.
Options can be protected on each protection level. However, option data
can only be entered in protection levels 0 and 1.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
Protection level concept
Locked by
Password
Password: SUNRISE (default)
Password: EVENING (default)
Password: CUSTOMER
(default)
Keylock switch position 3
Keylock switch position 2
Keylock switch position 1
Keylock switch position 0
Starting Up HMI Embedded (IM2)
4 Functions/Parameterization
Area
Siemens
Machine manufacturer:
Development
Machine manufacturer: Startup
engineer
End user: Servicing
End user: Programmer, machine
setter
End user: Skilled operator without
programming knowledge
End user: Trained operator
without programming knowledge
End user: Semi-skilled operator
IM2/4-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810dSinumerik 840diSinumerik 840d

Table of Contents