Siemens SINUMERIK 840D sl Commissioning Manual page 473

Commissioning cnc part 2 (hmi)
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

08/2005
Case 1:
Case 2:
Operating sequence
The transfer involves two steps:
1.
Copy the display machine data from the HMI Embedded System to an
external data medium.
2.
Insert the display machine data in the PCU 50/PCU 70 on the system with
HMI Advanced.
Case 1 (see drawing):
1.
On the system with HMI Advanced: Select the Services operating area.
2.
Transfer display machine data to the display, if not yet activated:
Services → Data Selection
Select "Display machine data"
OK
3.
Copy machine data:
Services → Manage Data
Display machine data\BDxxyy.tea
Copy
4.
Select target directory:
Diagnostics\MachineData\OperatorPanel
Paste
5.
Activate inserted display machine data via Start-up
Start-up → Machine Data → Display MD → File Functions
Set directory and BDxxyy.tea file
→ Load
Note
Systems with HMI Embedded manage more display machine data than systems
with HMI Advanced. A entry is made in the error log for all display machine data
that are offered but that are not defined in HMI Advanced or are faulty.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
HMI-Embedded
HMI Embedded
NCU1
Display MD
HMI-Advanced
HMI Advanced
Anzeige-MD
Display MD
Anzeige-MD
NCU1
HMI-Embedded
HMI Embedded
Display MD
Anzeige-MD
Commissioning HMI Advanced (IM4)
2 Functions/Parameterization
PCU 20
PCU 50
PCU 50
HMI Advanced
HMI-Advanced
Network LW
Netz-LW
Floppy Disk
Display MD
Anzeige-MD
NCU2
IM4/2-79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810dSinumerik 840diSinumerik 840d

Table of Contents