4. Select one of the following options:
Accept SNMP packets from any host
No further settings are required here.
Accept SNMP packets from these hosts
For the station to be monitored, enter the local address or the local computer name and the address of the
maintenance server (both addresses for a redundant MS server).
On the Maintenance Station, enter the local address or local computer name.
5. Under "Accepted community names", enter the name used in the configuration with read/write permissions.
6. Confirm your entries.

Configuring monitoring functions

Perform the configuration of the monitoring functions for all the monitored stations.
Requirement
You have started the SIMATIC IPC DiagMonitor Management Explorer with administrator rights.
1. Select "Start > SIMATIC DiagMonitor > Management Explorer".
2. Select the menu command "Station > Add...".
3. Select the "Local station" for which you want to monitor certain events.
4. Configure the desired events, for example, cyclic operating hour interrupts.
5. Confirm your entries.
Disabling automatic start of the SIMATIC IPC DiagMonitor Management
Explorer
The DiagMonitor monitoring software starts automatically when you log on to your device. The SIMATIC IPC DiagMonitor
Management Explorer configuration tool is then displayed automatically. You can disable this function.
1. Select the "Settings" item in the "Tools" menu of the SIMATIC IPC DiagMonitor Management Explorer configuration tool.
2. Disable the "Start with Windows" option.
3. Confirm your entries.

Configuring the maintenance stations

You can find information on how to monitor a PC station from the maintenance station in the "Configuring the maintenance
stations" chapter of the "Process Control System PCS 7 Maintenance Station" function manual.