If Expand user interface detects any errors when interpreting the screen form
configuration files, these will be stored in the file ERROR.COM
- with HMI Embedded and HT6 on the RAM drive,
- with HMI Advanced, in the directory \DH\COM.DIR\.
This file is deleted before every new screen form. It details
- which action was affected by an error,
- the line and column number of the first defective character and
- the whole defective line in the configuration file.
If the screen form was created using the PC test environment, then the error file
will be stored in the directory referenced by environment variable RAMDISK (HMI
Embedded /HT6). It can be read together with the communication error log in the
"Services" operating area by means of PCIN via the R-232 interface.
Editing in ERROR.COM
HMI Advanced:
Call the editor in the "Services" or "Start-Up" area.
HMI Embedded/HT6
Operating area "Start-Up", Access mode "Manufacturer", HMI, EDIT, New,
E:\ERROR.COM.
RAMDISK in on drive I:\ERROR.COM for PCU20.