Siemens SINUMERIK 840D sl Commissioning Manual page 424

Commissioning cnc part 2 (hmi)
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Commissioning HMI Advanced (IM4)
2 Setting Functions and Parameters
The following display, for example, appears in the program status line:
Figure 2-3
Deactivation
Icon displays configured in this way can be deactivated if user status displays are
used as described in B. Create empty entries in a user-specific HEADER.INI file
(not in the HMI_ADV directory, because this would be overwritten again when the
software is upgraded).
Example:
[Pos5]
SpindStat=<EMPTY>
User status display
Additionally (or alternatively), PLC-controlled (DB x, DBB y) user icons linked to
specific machine states can be output.
Procedure:
• Declaration of icons and positions (1.)
• Control of icon call by PLC (2.)
1. Enter the name of the user icons and the associated positions in the
HEADER.INI file in the UserIcons section under identifiers UI_0 to UI_31.
[UserIcons]
UI_0= <Icon_00.bmp> , <Position>
...
UI_31= <Icon_31.bmp> , <Position>
USER_ICON_BASE = DBx.DBBy
To display an icon according to the above declaration, the PLC sets the
corresponding bit in the double word.
IM4/2-30
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
; UI_0:
; Icon_00.bmp:
; Position:
Further on in the UserIcons section:
DBx.DBBy:
User-defined double word for
control of the icon selection. If a bit for
a user icon is set, the associated UI_x entry
should exist; otherwise, nothing will be displayed.
S3
Identifier
Name of user icon (8 characters.bmp)
Display position (1 to 16)
© Siemens AG, 2005. All rights reserved