Regie.ini - Siemens SINUMERIK 840D sl Commissioning Manual

Commissioning cnc part 2 (hmi)
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

08/2005

2.5.21 REGIE.INI

[Miscellaneous]
ExitButton= True
ExitbuttonIndex=15
ExitButtonAccessLevel=7
ExitButtonQueryUser = True
TemperatureMonitoring = False
References:
Hibernate (Windows XP only)
The HibernateMode parameter in the [Miscellaneous] section is used for setting
hibernation options.
These settings can also be made via the user interface of HMI Advanced. Select
"HMI" → "System Settings" in the "Startup" operating area.
HibernateMode = ...
The following values can be set:
HibernateMode = Off
HibernateMode = Normal
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
; needed if regie is to support an 'EXIT' button
; set 'ExitButton' to True, and 'ExitButtonIndex'
; identifies index of exit button
; The softkey text for this button MUST be entered into
; \mmc2\language\re_xx.ini
; where xx is the language abbreviation, e.g., :
; re_gr.ini (German text)
; re_uk.ini (English text)
; Protection level for exit button
; Dialog box to ask user
; Notes on other entries can be found in the OEM documentation
; Activating temperature monitoring for PCU50
; TemperatureMonitoring = True
OEM Package HMI, Chapter 6
Default: off
Hibernate saves and Hibernate reboots are not
performed.
HMI Advance first closes all applications. After the
shutdown, the controller is restarted automatically.
Commissioning HMI Advanced (IM4)
2 Functions/Parameterization
; Preset from
IM4/2-107

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810dSinumerik 840diSinumerik 840d

Table of Contents