Commissioning HMI Advanced (IM4)
2 Functions/Parameterization
Procedure for user-specific entries
1. In the F:\USER directory, create an empty INI file with the same name as in
"mmc2" (if necessary, also create subdirectories , e.g., LANGUAGE, in USER).
2. In the INI file in the USER directory, copy only the section you wish to change
and write the new or modified entry below it.
Note
Do not copy the entire INI file from "MMC2"!
Only copy the differences.
Example:
Entry in MBDDE.INI for PLC error message/operating message and scrolling
through alarm lines
MBDDE.INI in USER:
;Section header
[TextFiles]
UserPLC = F:\DH\MB.DIR\MYPLC_
[Alarms]
;Scroll through alarm lines
RotationCycle = 1000
The same procedure applies to the F:\ADD_ON and F:\OEM directories.
\ADD_ON is reserved for Siemens products.
All OEM applications should be installed in \OEM
!
Important
The associated entries, e.g. in REGIE.INI, should be modified in these directories
and not in \MMC2\!
Switching off settings
If there are specific entries in a lower-priority directory that you wish to be disabled
in a higher-priority directory, you can do this by specifying an <empty> entry
instead of a value.
Example:
Directory mmc2, file xxx.INI:
[<Section>]
<Identifier> = <value>
Directory user, file xxx.INI:
[<Section>]
<Identifier> = <empty>
IM4/2-54
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition