Siemens SINUMERIK 840D sl Commissioning Manual page 349

Commissioning cnc part 2 (hmi)
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

08/2005
5.3 Syntax of text file
5.3.1 File name
Only those file names listed under "Editable alarm text files" in the previous section
may be used.
5.3.2 Example of an alpu.txt file
// CP = 1252
// IDEO = NO
// ANSI = YES
// UNICODE = NO
// VERSION = $VERSION
[SWITCHES]/ALARM
//**********************************************************************/
//* PLC user alarm file
//**********************************************************************/
//* User entries:
//* p.e.
//* 800001 0 0 "Safety door faulty, error analysis required"
//* max. 62 characters!
//* Area for Application: 700000-799999,800000-809999,811000-819999
*/
//*******************************************************************/
Header
The text files begin with several comments, which contain information for the
runtime system.
You can enter texts that can be assigned freely after "[SWITCHES]/ALARM".
// CP = XXXX
// IDEO =
// ANSI =
// UNICODE =
// VERSION =
Comment
You can insert comments before every line in the alarm text file. These comments
have to begin with "//".
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
Number of the code page used to create the file (ANSI table, see
Table 5-5)
Use of Asian text:
Yes: Logographic language
No: Single-byte language (default: No)
File format of the text file
Yes: ANSI code page
No: OEM code page (default: No)
File format of the text file
Yes: Unicode
No: Single-byte (default: No)
Version identifier
Starting Up HMI Embedded (IM2)
5 Creating In-House Alarm Texts
IM2/5-99
*/
*/
*/
*/
*/