FC 300 Design Guide
Parameters: Operation
"
and Display
0-0* Basic Settings
"
0-01 Language
Option:
*
English (ENGLISH)
German (DEUTSCH)
French (FRANCAIS)
Danish (DANSK)
Spanish (ESPANOL)
Italian (ITALIANO)
Chinese (CHINESE)
Finnish (FINNISH)
English US (ENGLISH US)
Greek (GREEK)
Portuguese (PORTUGUESE)
Slovenian (SLOVENIAN)
Korean (KOREAN)
Japanese (JAPANESE)
Turkish (TURKISH)
Traditional Chinese
Bulgarian
Serbian
Romanian (ROMANIAN)
Hungarian (HUNGARIAN)
Czech
Polish (POLISH)
Russian
Thai
Bahasa Indonesian (BAHASA
INDONESIAN)
Function:
Defines the language to be used in display.
The frequency converter can be delivered with
4 various language packages. English and
German are included in all packages. English
cannot be erased or manipulated.
0-02 Motor Speed Unit
Option:
*
RPM
Hz
Function:
Defines the parameters for motor speed (i.e.
references, feedbacks, limits) displayed in terms
of shaft speed (in RPM) or the output frequency
to the motor (Hz). This parameter cannot be
adjusted while the motor is running.
default setting
( )
*
134
How to Programme
[0]
[1]
[2]
[3]
[4]
[5]
[10]
[20]
[22]
[27]
[28]
[36]
[39]
[40]
[41]
[42]
[43]
[44]
[45]
[46]
[47]
[48]
[49]
[50]
[51]
[0]
[1]
display text
[ ]
value for use in communication via serial communication port
MG.33.B4.02 - VLT is a registered Danfoss trademark
0-03 Regional Settings
Option:
*
International
US
Function:
Select International [0] to set the unit of par.1-20
Motor Power in kW and the default setting of par.
1-23 to 50 Hz. Select "[1] US" to set the unit
of par. 1-21 Motor Power in HP and the default
value of par. 1-23 to 60 Hz. Par. 0-03 cannot
be adjusted while the motor is running.
0-04 Operating State at Power-up (Hand)
Option:
Resume
*
Forced stop, ref=old
Forced stop, ref = 0
Function:
Sets the operating mode when mains voltage
is reconnected after power down in Hand
(local) operation.
Select Resume [0] start up the drive with the
same local reference and the same start/stop
conditions (applied by [START/STOP] ) as before
the drive was switched off.
Use Forced stop, use saved reference [1] to stop
the drive until mains voltage reappears and until
you press [START]. After the start command, the
saved local ref. will be set automatically.
Select Forced stop, set reference to 0 [2] to
stop the drive until mains voltage reappears.
Local reference is reset.
0-1* Set-Up Handling
"
Parameters to select and control the individual
parameter set-ups.
0-10 Active Set-up
Option:
Factory setup
*
Set-up 1
Set-up 2
Set-up 3
Set-up 4
Multi set-up
Function:
Defines the Set-up number to control the
functions of the drive.
[0]
[1]
[0]
[1]
[2]
[0]
[1]
[2]
[3]
[4]
[9]