FC 300 Design Guide
0-2* LCP Display
"
Parameter group for setting the display in
the Graphical Logic Control Panel. Following
options are available:
0-20 Display Line 1.1 Small
None
Profibus Warning Word
Readout Transmit Error Counter
Readout Receive Error Counter
Readout Bus Off Counter
Warning Parameter
Running Hours
kWh Counter
Control Word
Reference [Unit]
Reference %
Status Word
Main Actual Value [Unit]
Main Actual Value [Unit]
Custom Readout
Power [kW]
Power [hp]
Motor Voltage
Frequency
Motor Current
Frequency [%]
Torque
* Speed [RPM]
Motor Thermal
KTY Sensor Temperature
Motor Angle
Phase Angle
DC Link Voltage
BrakeEnergy/s
BrakeEnergy/2 min
Heatsink Temp.
Inverter Thermal
Inv. Nom. Current
Inv. Max. Current
SL Control State
Control Card Temp.
External Reference
Pulse Reference
Feedback [Unit]
Digi Pot Reference
Digital Input
Terminal 53 Switch Setting
Analog Input 53
Terminal 54 Switch Setting
Analog Input 54
Analog Output 42 [mA]
Digital Output [bin]
Freq. Input #29 [Hz]
Freq. Input #33 [Hz]
Pulse Output #27 [Hz]
Pulse Output #29 [Hz]
Relay Output [bin]
Counter A
Counter B
Fieldbus CTW 1
Fieldbus REF 1
default setting
( )
*
How to Programme
[953]
[1005]
[1006]
[1007]
[1013]
[1501]
[1502]
[1600]
[1601]
[1602]
[1603]
[1604]
[1605]
[1609]
[1610]
[1611]
[1612]
[1613]
[1614]
[1615]
[1616]
[1617]
[1618]
[1619]
[1620]
[1621]
[1630]
[1632]
[1633]
[1634]
[1635]
[1636]
[1637]
[1638]
[1639]
[1650]
[1651]
[1652]
[1653]
[1660]
[1661]
[1662]
[1663]
[1664]
[1665]
[1666]
[1667]
[1668]
[1669]
[1670]
[1671]
[1672]
[1673]
[1680]
[1682]
display text
[ ]
value for use in communication via serial communication port
MG.33.B4.02 - VLT is a registered Danfoss trademark
Comm. Option STW
FC Port CTW 1
FC Port REF 1
Alarm Word
Alarm Word 2
Warning Word
Warning Word 2
Ext. Status Word
[0]
Ext. Status Word 2
PCD 1 Write to MCO
PCD 2 Write to MCO
PCD 3 Write to MCO
PCD 4 Write to MCO
PCD 5 Write to MCO
PCD 6 Write to MCO
PCD 7 Write to MCO
PCD 8 Write to MCO
PCD 9 Write to MCO
PCD 10 Write to MCO
PCD 1 Read from MCO
PCD 2 Read from MCO
PCD 3 Read from MCO
PCD 4 Read from MCO
PCD 5 Read from MCO
PCD 6 Read from MCO
PCD 7 Read from MCO
PCD 8 Read from MCO
PCD 9 Read from MCO
PCD 10 Read from MCO
Digital Inputs
Digital Outputs
Actual Position
Commanded Position
Actual Master Position
Slave Index Position
Master Index Position
Curve Position
Track Error
Synchronizing Error
Actual Velocity
Actual Master Velocity
Synchronizing Status
Axis Status
Program Status
Idle Time
Paramdb Requests in Queue
Function:
None [0]
No display value chosen
Control Word [1600]
present control word
Reference [Unit] [1601]
of terminals 53 or 54 using the unit stated on the
basis of configuration in P.1-00 (RPM or Nm).
Reference % [1602]
reference (sum of digital/analog/preset/bus/freeze
ref./catch-up and slow-down).
Status Word [binary] [1603]
the present status word
Alarm Word [1604]
alarms in a Hex code.
[1684]
[1685]
[1686]
[1690]
[1691]
[1692]
[1693]
[1694]
[1695]
[3401]
[3402]
[3403]
[3404]
[3405]
[3406]
[3407]
[3408]
[3409]
[3410]
[3421]
[3422]
[3423]
[3424]
[3425]
[3426]
[3427]
[3428]
[3429]
[3430]
[3440]
[3441]
[3450]
[3451]
[3452]
[3453]
[3454]
[3455]
[3456]
[3457]
[3458]
[3459]
[3460]
[3461]
[3462]
[9913]
[9914]
Displays the
displays the status value
displays the total
Displays
indicates one or several
137