FC 300 Design Guide

Access to Control Terminals

"
All terminals to the control cables are located
underneath the terminal cover on the front of the
frequency converter. Remove the terminal cover
by means of a screwdriver (see illustration).

Electrical Installation, Control Terminals

"
Mount terminals from the accessory bag
1.
to the front of the FC 300.
Connect terminals 18, 27, and 37 to +24 V
2.
(terminal 12/13) with the control cable.
Default settings:
18 = start
27 = coast inverse
37 = safe stop inverse
NB!:
To mount the cable to the terminal:
Strip isolation of 9-10 mm
1.
Insert a screw driver in the square hole.
2.
Insert the cable in the adjacent circular hole.
3.
4.
Remove the screw driver. The cable is now
mounted to the terminal.