Danfoss VLT AutomationDrive FC 300 Design Manual page 234

Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

FC 300 Design Guide
16-** Data Readouts
"
Par.
Parameter description
No.
#
16-0* General Status
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status Word
16-05 Main Actual Value [%]
16-1* Motor Status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor Current
16-15 Frequency [%]
16-16 Torque
16-17 Speed [RPM]
16-18 Motor Thermal
16-20 Motor Angle
16-3* Drive Status
16-30 DC Link Voltage
16-32 Brake Energy /s
16-33 Brake Energy /2 min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-36 Inv. Nom. Current
16-37 Inv. Max. Current
16-38 SL Controller State
16-39 Control Card Temp.
16-40 Logging Buffer Full
16-5* Ref. & Feedb.
16-50 External Reference
16-51 Pulse Reference
16-52 Feedback [Unit]
16-53 Digi Pot Reference
16-6* Inputs & Outputs
16-60 Digital Input
16-61 Terminal 53 Switch Setting
16-62 Analog Input 53
16-63 Terminal 54 Switch Setting
16-64 Analog Input 54
16-65 Analog Output 42 [mA]
16-66 Digital Output [bin]
16-67 Freq. Input #29 [Hz]
16-68 Freq. Input #33 [Hz]
16-69 Pulse Output #27 [Hz]
16-70 Pulse Output #29 [Hz]
16-71 Relay Output [bin]
16-72 Counter A
16-73 Counter B
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1
16-82 Fieldbus REF 1
16-84 Comm. Option STW
16-85 FC Port CTW 1
16-86 FC Port REF 1
16-9* Diagnosis Readouts
16-90 Alarm Word
16-92 Warning Word
16-94 Ext. Status Word
default setting
( )
*
234
How to Programme
Default value
0 N/A
0.000 ReferenceFeedbackUnit
0.0 %
0 N/A
0.00 %
0.00 kW
0.00 hp
0.0 V
0.0 Hz
0.00 A
0.00 %
0.0 Nm
0 RPM
0 N/A
0.000 kW
0.000 kW
ExpressionLimit
ExpressionLimit
0 N/A
[0] No
0.0 N/A
0.0 N/A
0.000 ReferenceFeedbackUnit
0.00 N/A
0 N/A
[0] Current
0.000 N/A
[0] Current
0.000 N/A
0.000 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
display text
[ ]
value for use in communication via serial communication port
MG.33.B4.02 - VLT is a registered Danfoss trademark
4-set-up
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
0 %
All set-ups
All set-ups
0 V
All set-ups
All set-ups
All set-ups
0 °C
All set-ups
0 %
All set-ups
All set-ups
All set-ups
All set-ups
0 °C
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
FC 302
Change
Con-
only
during
ver-
opera-
sion
tion
index
FALSE
0
FALSE
-3
Int32
FALSE
-1
Int16
FALSE
0
FALSE
-2
FALSE
1
Int32
FALSE
-2
Int32
FALSE
-1
Uint16
FALSE
-1
Uint16
FALSE
-2
Int32
FALSE
-2
FALSE
-1
Int16
FALSE
67
Int32
FALSE
0
Uint8
FALSE
0
Uint16
FALSE
0
Uint16
FALSE
0
Uint32
FALSE
0
Uint32
FALSE
100
Uint8
FALSE
0
Uint8
FALSE
-2
Uint32
FALSE
-2
Uint32
FALSE
0
Uint8
FALSE
100
Uint8
FALSE
-
Uint8
FALSE
-1
Int16
FALSE
-1
Int16
FALSE
-3
Int32
FALSE
-2
Int16
FALSE
0
Uint16
FALSE
-
Uint8
FALSE
-3
Int32
FALSE
-
Uint8
FALSE
-3
Int32
FALSE
-3
Int16
FALSE
0
Int16
x
FALSE
0
Int32
FALSE
0
Int32
FALSE
0
Int32
x
FALSE
0
Int32
FALSE
0
Int16
FALSE
0
Int32
FALSE
0
Int32
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
Uint32
FALSE
0
Uint32
FALSE
0
Uint32
Type
V2
V2
N2
N2
V2
N2
V2
V2
N2